Detection of CrO4(2-) using a hydrogel swelling microcantilever sensor.

Hydrogels containing various mounts of tetraalkylammonium salts were used to modify microcantilevers for measurements of the concentration of CrO4(2-) in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various CrO4(2-) concentrations as a result of swelling or shrinking of the hydrogels. The microcantilever deflection as a function of the concentration of CrO4(2-) ions is nearly linear in most concentration ranges. It was found that a concentration of 10(-11) M CrO4(2-) can be detected using this technology in a fluid cell. Other ions, such as Br-, HPO4(2-), and NO3-, have minimal effect on the deflection of this cantilever. The anions SO4(2-) and CO3(2-) could interfere with the CrO4(2-) detection, but only at high concentrations (> 10(-5) M). Such hydrogel-coated microcantilevers could potentially be used to prepare microcantilever-based chemical and biological sensors when molecular recognition agents are immobilized in the hydrogel.

[1]  James K. Gimzewski,et al.  Stress at the Solid−Liquid Interface of Self-Assembled Monolayers on Gold Investigated with a Nanomechanical Sensor , 2000 .

[2]  A. Hierlemann,et al.  Complementary metal oxide semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds. , 2002, Analytical chemistry.

[3]  Thomas Thundat,et al.  Vapor detection using resonating microcantilevers , 1995 .

[4]  S. Gehrke Synthesis, equilibrium swelling, kinetics, permeability and applications of environmentally responsive gels , 1993 .

[5]  Yoshihito Osada,et al.  Stimuli-responsive polymer gels and their application to chemomechanical systems , 1993 .

[6]  Masahiro Irie,et al.  Stimuli-responsive polymers: chemical induced reversible phase separation of an aqueous solution of poly(N-isopropylacrylamide) with pendent crown ether groups , 1993 .

[7]  S. Asher,et al.  Intelligent Polymerized Crystalline Colloidal Arrays: Novel Chemical Sensor Materials , 1998 .

[8]  Masayuki Tokita,et al.  Phase Transitions of Gels , 1992 .

[9]  Sonja Krause,et al.  An electrorheological fluid and siloxane gel based electromechanical actuator: Working toward an artificial muscle , 1998 .

[10]  M. Grattarola,et al.  Micromechanical cantilever-based biosensors , 2001 .

[11]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[12]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[13]  Vijay S. Pande,et al.  Polymer gels that can recognize and recover molecules , 1995 .

[14]  J. Bond,et al.  The effects of cisplatin and other divalent platinum compounds on glucose metabolism and pancreatic endocrine function. , 1983, Toxicology and applied pharmacology.

[15]  James K. Gimzewski,et al.  A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout , 2001 .

[16]  T. Thundat,et al.  Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches. , 2001, Analytical chemistry.

[17]  James K. Gimzewski,et al.  An artificial nose based on a micromechanical cantilever array , 1999 .

[18]  M. Irie Stimuli-responsive poly(N-isopropylacrylamide). Photo- and chemical-induced phase transitions , 1993 .

[19]  Udo Weimar,et al.  Multicomponent analysis and prediction with a cantilever array based gas sensor , 2001 .

[20]  Oguz H. Elibol,et al.  Micromechanical cantilever as an ultrasensitive pH microsensor , 2002 .

[21]  M. F. McCurley,et al.  An optical biosensor using a fluorescent, swelling sensing element , 1994 .

[22]  A. Shaun Francomacaro,et al.  Microfabricated conductimetric pH sensor , 1995 .

[23]  E. Kramarenko,et al.  Weakly Charged Polyelectrolytes: Collapse Induced by Extra Ionization , 1996 .

[24]  Stephen J. Martin,et al.  Dynamics and Response of Polymer-Coated Surface Acoustic Wave Devices: Effect of Viscoelastic Properties and Film Resonance , 1994 .

[25]  S. Asher,et al.  Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials , 1997, Nature.

[26]  Michael P. Eastman,et al.  Sensor based on piezoresistive microcantilever technology , 2001 .

[27]  Teruo Okano,et al.  Sensitive glucose-induced change of the lower critical solution temperature of poly [N,N-dimethylacrylamide-co-3-(acrylamido) phenyl-boronic acid] in physiological saline , 1994 .

[28]  Toyoichi Tanaka Collapse of Gels and the Critical Endpoint , 1978 .