Numerical simulation of flow in mechanical heart valves: grid resolution and the assumption of flow symmetry.

A numerical method is developed for simulating unsteady, 3-D, laminar flow through a bileaflet mechanical heart valve with the leaflets fixed. The method employs a dual-time-stepping artificial-compressibility approach together with overset (Chimera) grids and is second-order accurate in space and time. Calculations are carried out for the full 3-D valve geometry under steady inflow conditions on meshes with a total number of nodes ranging from 4 x 10(5) to 1.6 x 10(6). The computed results show that downstream of the leaflets the flow is dominated by two pairs of counter-rotating vortices, which originate on either side of the central orifice in the aortic sinus and rotate such that the common flow of each pair is directed away from the aortic wall. These vortices intensify with Reynolds number, and at a Reynolds number of approximately 1200 their complex interaction leads to the onset of unsteady flow and the break of symmetry with respect to both geometric planes of symmetry. Our results show the highly 3-D structure of the flow; question the validity of computationally expedient assumptions of flow symmetry; and demonstrate the need for highly resolved, fully 3-D simulations if computational fluid dynamics is to accurately predict the flow in prosthetic mechanical heart valves.

[1]  Jack Lemmon,et al.  A numerical simulation of mechanical heart valve closure fluid dynamics. , 2002, Journal of biomechanics.

[2]  A. Yoganathan,et al.  Flow characteristics of the St. Jude prosthetic valve: an in vitro and in vivo study. , 2008, Artificial organs.

[3]  Fotis Sotiropoulos,et al.  Assessment of artificial dissipation models for three- dimensional incompressible flow solutions , 1997 .

[4]  J Fisher,et al.  Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve. , 1997, Medical engineering & physics.

[5]  Shmuel Einav,et al.  Unsteady effects on the flow across tilting disk valves. , 2002, Journal of biomechanical engineering.

[6]  Fotis Sotiropoulos,et al.  Transition from bubble-type vortex breakdown to columnar vortex in a confined swirling flow , 1998 .

[7]  K. B. Chandran,et al.  Numerical Simulation of Mechanical Mitral Heart Valve Closure , 2001, Annals of Biomedical Engineering.

[8]  Fotis Sotiropoulos,et al.  Strongly-Coupled Multigrid Method for 3-D Incompressible Flows Using Near-Wall Turbulence Closures , 1997 .

[9]  M Cerrolaza,et al.  Analysis of 3D transient blood flow passing through an artificial aortic valve by Lattice-Boltzmann methods. , 1998, Journal of biomechanics.

[10]  A. Spence,et al.  Is the steady viscous incompressible two‐dimensional flow over a backward‐facing step at Re = 800 stable? , 1993 .

[11]  J. L. Steger,et al.  On the use of composite grid schemes in computational aerodynamics , 1987 .

[12]  Timothy M. Healy Multi-block and overset-block domain decomposition techniques for cardiovascular flow simulation , 2001 .

[13]  Charles Merkle,et al.  Time-accurate unsteady incompressible flow algorithms based on artificial compressibility , 1987 .

[14]  J. Tarbell,et al.  Numerical simulation of unsteady laminar flow through a tilting disk heart valve: prediction of vortex shedding. , 1994, Journal of biomechanics.

[15]  C. Peskin Flow patterns around heart valves: A numerical method , 1972 .

[16]  John Fisher,et al.  An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics , 1994 .

[17]  David A Steinman,et al.  A dual-pressure boundary condition for use in simulations of bifurcating conduits. , 2002, Journal of biomechanical engineering.

[18]  Fotis Sotiropoulos,et al.  An overset-grid method for 3D unsteady incompressible flows , 2003 .

[19]  F. Nicoud,et al.  Integral boundary conditions for unsteady biomedical CFD applications , 2002 .

[20]  E B Shim,et al.  Numerical analysis of three-dimensional Björk-Shiley valvular flow in an aorta. , 1997, Journal of biomechanical engineering.

[21]  J Fisher,et al.  A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: comparison of experimental and numerical results. , 1996, Journal of biomechanics.

[22]  Mark W. Johnson,et al.  Flow Instability in a Curved Duct of Rectangular Cross Section , 1992 .

[23]  D Kwak,et al.  Computational approach for probing the flow through artificial heart devices. , 1997, Journal of biomechanical engineering.

[24]  K. Thompson Time-dependent boundary conditions for hyperbolic systems, II , 1990 .