Treatment of proximal humerus fractures with locking plates: a systematic review.

HYPOTHESIS Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. METHODS Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). RESULTS Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. DISCUSSION The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results. LEVEL OF EVIDENCE Systematic Review.

[1]  A. J. Wijgman,et al.  Open Reduction and Internal Fixation of Three and Four-Part Fractures of the Proximal Part of the Humerus , 2002, The Journal of bone and joint surgery. American volume.

[2]  R. Esser Open reduction and internal fixation of three- and four-part fractures of the proximal humerus. , 1994, Clinical orthopaedics and related research.

[3]  O. Trentz,et al.  Internal fixation of displaced proximal humeral fractures with two one-third tubular plates. , 2003, The Journal of trauma.

[4]  G. Duda,et al.  Proximal humeral fractures: how stiff should an implant be? , 2003, Archives of Orthopaedic and Trauma Surgery.

[5]  R. Page,et al.  Severely impacted valgus proximal humeral fractures. Results of operative treatment. , 2003, The Journal of bone and joint surgery. American volume.

[6]  H. Vallier Treatment of proximal humerus fractures. , 2007, Journal of orthopaedic trauma.

[7]  M. Plecko,et al.  Internal fixation of proximal humerus fractures using the locking proximal humerus plate. , 2005, Operative Orthopadie und Traumatologie.

[8]  J. Macdermid,et al.  Proximal humeral fractures: a systematic review of treatment modalities. , 2008, Journal of shoulder and elbow surgery.

[9]  A. Amis,et al.  Failure of humeral fracture fixation plate in a young patient using the Philos system: case report. , 2006, Journal of shoulder and elbow surgery.

[10]  C. Charalambous,et al.  Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures , 2007, Archives of Orthopaedic and Trauma Surgery.

[11]  C. Court-Brown,et al.  Epidemiology of adult fractures: A review. , 2006, Injury.

[12]  O. Bach,et al.  Humeruskopffrakturen - winkelstabile Plattenosteosynthese , 2003 .

[13]  G. Muhr,et al.  Operative und klinische Erfahrungen mit winkelstabilen Implantaten bei proximalen Humerusfrakturen - Wirklich alles besser? , 2007 .

[14]  M. Leunig,et al.  Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. , 2004, Journal of shoulder and elbow surgery.

[15]  W. Wallace,et al.  Closed percutaneous K-wire stabilization for displaced fractures of the surgical neck of the humerus. , 1990, Injury.

[16]  C. Charalambides,et al.  Early failure of intramedullary nailing for proximal humeral fractures. , 2000, Injury.

[17]  Florian Fankhauser,et al.  A New Locking Plate for Unstable Fractures of the Proximal Humerus , 2005, Clinical orthopaedics and related research.

[18]  C. Voigt,et al.  Komplikationsmanagement nach winkelstabiler Plattenosteosynthese am proximalen Humerus , 2006, Der Chirurg.

[19]  M. Plecko,et al.  Die winkelstabile Plattenosteosynthese bei Frakturen am proximalen Humerus mit der LPHP (Locking Proximal Humerus Plate) , 2005, Operative Orthopädie und Traumatologie.

[20]  P. Kannus,et al.  Update in the Epidemiology of Proximal Humeral Fractures , 2006, Clinical orthopaedics and related research.

[21]  C. Neer Displaced Proximal Humeral Fractures , 1970 .

[22]  J. Agel,et al.  Treatment of proximal humeral fractures with Polarus nail fixation. , 2004, Journal of shoulder and elbow surgery.

[23]  Michael J Gardner,et al.  The Importance of Medial Support in Locked Plating of Proximal Humerus Fractures , 2007, Journal of orthopaedic trauma.

[24]  C. Sommer,et al.  Guidelines for the clinical application of the LCP. , 2003, Injury.

[25]  M. Allgöwer,et al.  Manual of INTERNAL FIXATION , 1992, Springer Berlin Heidelberg.

[26]  B. Kristiansen,et al.  Plate fixation of proximal humeral fractures. , 1986, Acta orthopaedica Scandinavica.

[27]  D. Korres,et al.  Fixation of Proximal Humerus Fractures Using the PHILOS Plate: Early Experience , 2006, Clinical orthopaedics and related research.

[28]  P. Biberthaler,et al.  Die winkelstabile Osteosynthese am proximalen Humerus mit der PHILOS-Platte , 2006, Der Unfallchirurg.

[29]  W Mutschler,et al.  [Treatment of proximal humeral fractures with the PHILOS angular stable plate. Presentation of 225 cases of dislocated fractures]. , 2006, Der Unfallchirurg.

[30]  D. Jacofsky,et al.  Locking plate fixation for proximal humeral fractures: initial results with a new implant. , 2007, Journal of shoulder and elbow surgery.

[31]  J. Pajarinen,et al.  Internal fixation of proximal humeral fractures with a locking compression plateA retrospective evaluation of 72 patients followed for a minimum of 1 year , 2004, Acta orthopaedica Scandinavica.

[32]  C. Constant,et al.  A clinical method of functional assessment of the shoulder. , 1987, Clinical orthopaedics and related research.

[33]  H. Lill,et al.  [The angle stable locking-proximal-humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results]. , 2004, Zentralblatt fur Chirurgie.

[34]  M. Karagas,et al.  The epidemiology of peripheral fractures. , 1996, Bone.

[35]  H. Resch,et al.  Percutaneous Fixation Of Three- And Four-part Fractures Of The Proximal Humerus , 1997 .

[36]  B. Füchtmeier,et al.  Die Versorgung dislozierter 3- und 4-Fragmentfrakturen des proximalen Humerus mit einem winkelstabilen Plattenfixateur , 2004, Der Unfallchirurg.