Non-coplanar beam intensity modulation allows large dose escalation in stage III lung cancer.

PURPOSE To evaluate the feasibility of dose escalation in stage III non-small cell lung cancer, we compared standard coplanar (2D) with non-coplanar beam arrangements, without (3D) and with beam intensity modulation (3D-BIM). MATERIALS AND METHODS This study was a planning effort performed on a non-selected group of 10 patients. Starting from a serial CT scan, treatment planning was performed using Sherouse's GRATIS 3D planning system. Two target volumes were defined; gross tumor volume (GTV) defined a high-dose target volume that had to receive a dose of at least 80 Gy and GTV plus the lymph node regions with >10% probability of invasion defined an intermediate-dose target volume (GTV + N). It was our intention to irradiate GTV + N up to 56 Gy or more. If the prescribed doses on GTV and GTV + N could not be reached with either the 2D or 3D technique, a 3D-BIM plan was performed. The 3D-BIM plan was a class solution involving identical gantry angles, segment arrangements and relative segment weights for all patients. Dose volume histograms for GTV, GTV + N, lung and spinal cord were calculated. Criteria for tolerance were met if no points inside the spinal cord exceeded 50 Gy and if at least 50% of the lung volume received less than 20 Gy. Under these constraints, maximal achievable doses to GTV and GTV + N were calculated. RESULTS In all 2D plans, spinal cord was the limiting factor and the prescribed doses for GTV and GTV + N could not be reached in any patient. The non-coplanar 3D plan resulted in a satisfying solution in 4 out of 10 patients under the same constraints. In comparison with 2D, the minimum dose in GTV + N was increased. Six patients had to be planned with the 3D-BIM technique. The theoretical minimum dose to GTV + N ranged between 56 and 98 Gy. The delivery of 80 Gy or more to GTV was possible in all patients. For a minimal dose of 80 Gy to GTV, the maximal dose to any point of the spinal cord varied between 27 and 46 Gy. The lung volume receiving more than 20 Gy ranged from 26 to 46%. CONCLUSION The potential of 3D-BIM for dose escalation is explained as follows: (i) compared to other planning techniques, a larger amount of lung tissue can be spared by using beam directions that are well-aligned with the mediastinal structures. Such beam directions have narrow angles with the sagittal plane; (ii) dividing all beams into segments with well-specified geometrical restrictions in relation to the spinal cord and well-defined relative weights results in a lower dose to the spinal cord.

[1]  T. Pajak,et al.  Interruptions of high-dose radiation therapy decrease long-term survival of favorable patients with unresectable non-small cell carcinoma of the lung: analysis of 1244 cases from 3 Radiation Therapy Oncology Group (RTOG) trials. , 1993, International journal of radiation oncology, biology, physics.

[2]  C. Mountain,et al.  Prognostic implications of the International Staging System for Lung Cancer. , 1988, Seminars in oncology.

[3]  J. Purdy,et al.  Preliminary results of a prospective trial using three dimensional radiotherapy for lung cancer. , 1995, International journal of radiation oncology, biology, physics.

[4]  P Kijewski,et al.  The effect on minimum tumor dose of restricting target-dose inhomogeneity in optimized three-dimensional treatment of lung cancer. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  M. Martel,et al.  Results of high-dose thoracic irradiation incorporating beam's eye view display in non-small cell lung cancer: a retrospective multivariate analysis. , 1993, International journal of radiation oncology, biology, physics.

[6]  Gain in target dose from using Computer Controlled Radiation Therapy (CCRT) in the treatment of non-small cell lung cancer. , 1993, International journal of radiation oncology, biology, physics.

[7]  R Mohan,et al.  Optimization of intensity-modulated 3D conformal treatment plans based on biological indices. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  E. Chaney,et al.  The portable virtual simulator. , 1991, International journal of radiation oncology, biology, physics.

[9]  G J Kutcher,et al.  The potential and limitations of the inverse radiotherapy technique. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  T. Pajak,et al.  Dose intensity of radiation therapy in non-small cell carcinoma of the lung: a review of RTOG data and strategies. , 1994, Lung cancer.

[11]  C. Coleman,et al.  Hypoxic cell radiosensitizers: expectations and progress in drug development. , 1985, International journal of radiation oncology, biology, physics.

[12]  G. Sherouse A mathematical basis for selection of wedge angle and orientation. , 1993, Medical physics.

[13]  C De Wagter,et al.  Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed with a multileaf collimator. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  H S Glazer,et al.  Three-dimensional radiation treatment planning study for patients with carcinoma of the lung. , 1994, International journal of radiation oncology, biology, physics.