Optimal Identification and selection of Phasor Measurement Units- A Methodology

The Phasor measurement unit (PMU) is becoming an important tool for monitoring, controlling and protecting the electric networks. Hence its deployment for the present and future power system networks has become a great challenge for the planning engineers. The optimal PMU placement (OPP) is quite important strategy for deploying the PMUs optimally. Since the optimization techniques yield multiple solutions, it has become an important task again for the engineers to select the best set out of all the available solutions of results. This paper, after presenting the literature on various optimization methods used for solving OPP problem, suggests Multiple Criteria Decision Making (MCDM) methods to select the suitable solution based on the criteria.

[1]  Ying-Hong Lin,et al.  An adaptive PMU based fault detection/location technique for transmission lines. I. Theory and algorithms , 2000 .

[2]  A. Abur,et al.  Placement of PMUs to Enable Bad Data Detection in State Estimation , 2006, IEEE Transactions on Power Systems.

[3]  Jianfeng Guo,et al.  Multi-objective optimal PMU placement using a non-dominated sorting differential evolution algorithm , 2010 .

[4]  Randy L. Haupt,et al.  Practical Genetic Algorithms , 1998 .

[5]  Babak Mozafari,et al.  Optimal placement of PMUs to maintain network observability using a modified BPSO algorithm , 2011 .

[6]  James S. Thorp,et al.  A PMU Placement Scheme Ensuring Real-Time Monitoring of Critical Buses of the Network , 2014, IEEE Transactions on Power Delivery.

[7]  Michaël Hurtgen,et al.  Optimal PMU placement using Iterated Local Search , 2010 .

[8]  S.A. Soman,et al.  Optimal Multistage Scheduling of PMU Placement: An ILP Approach , 2008, IEEE Transactions on Power Delivery.

[9]  Li Ying,et al.  Sensitivity Constrained PMU Placement for Complete Observability of Power Systems , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[10]  Demetrios G. Eliades,et al.  Placement of Synchronized Measurements for Power System Observability , 2009, IEEE Transactions on Power Delivery.

[11]  T. Baldwin,et al.  Power system observability with minimal phasor measurement placement , 1993 .

[12]  Ravikumar Bhimasingu,et al.  An approach for optimal placement of Phasor Measurement Units considering fuzzy logic based critical buses , 2013, 2013 IEEE International Conference on Smart Energy Grid Engineering (SEGE).

[13]  M. Fotuhi-Firuzabad,et al.  Optimal Placement of Phasor Measurement Units Using Immunity Genetic Algorithm , 2009, IEEE Transactions on Power Delivery.

[14]  Evangelos Triantaphyllou,et al.  Multi-criteria Decision Making Methods: A Comparative Study , 2000 .

[15]  T.S. Sidhu,et al.  Impact of TCSC on the protection of transmission lines , 2006, IEEE Transactions on Power Delivery.

[16]  Y. Alinejad-Beromi,et al.  Optimal PMU placement for power system observability using binary particle swarm optimization and considering measurement redundancy , 2011, Expert Syst. Appl..

[17]  Joong-Rin Shin,et al.  Optimal placement of phasor measurement units with GPS receiver , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[18]  A.G. Phadke,et al.  Phasor measurement unit placement techniques for complete and incomplete observability , 2005, IEEE Transactions on Power Delivery.

[19]  H. Vincent Poor,et al.  Strategic Protection Against Data Injection Attacks on Power Grids , 2011, IEEE Transactions on Smart Grid.