Electronic crosstalk correction for terra long wave infrared photovoltaic bands

The MODerate-resolution Imaging Spectroradiometer (MODIS) is one of the primary instruments in the National Aeronautics and Space Administration (NASA) Earth Observing System (EOS). The first MODIS instrument was launched in December 1999 on-board the Terra spacecraft. MODIS has 36 bands, among which 27-30 are Long Wave Infrared (LWIR) PhotoVoltaic (PV) bands covering a wavelength range from 6.72 μm to 9.73 μm. It has been found that there is severe contamination in Terra band 27 from other three bands due to crosstalk of signals among them. The crosstalk effect induces strong striping in the Earth View (EV) images and causes large long-term drift in the EV Brightness Temperature (BT) in the band. An algorithm using a linear approximation derived from on-orbit lunar observations has been developed to correct the crosstalk effect for band 27. It was demonstrated that the crosstalk correction can substantially reduce the striping in the EV images and significantly remove the long-term drift in the EV BT. In this paper, it is shown that other three LWIR PV bands are also contaminated by the crosstalk of signals among themselves. The effect induces strong striping artifacts and large long-term drifts in these bands as similarly observed in band 27. The crosstalk correction algorithm previously developed is applied to correct the crosstalk effect. It is demonstrated that the crosstalk correction successfully reduces the striping in the EV images and removes long-term drifts in the EV BT in bands 28-30 as was done similarly for band 27. The crosstalk correction algorithm can thus substantially improve both the image quality and radiometric accuracy of the LWIR PV bands Level 1B (L1B) products. The algorithm can be applied to other MODIS bands and/or other remote sensors that exhibit an electronic crosstalk effect.

[1]  P. Abel,et al.  MODIS Calibration: A Brief Review of the Strategy for the At-Launch Calibration Approach , 1996 .

[2]  Aisheng Wu,et al.  Multiyear On-Orbit Calibration and Performance of Terra MODIS Thermal Emissive Bands , 2008, IEEE Transactions on Geoscience and Remote Sensing.

[3]  Xiaoxiong Xiong,et al.  MODIS Reflective Solar Bands On-Orbit Lunar Calibration , 2007, IEEE Transactions on Geoscience and Remote Sensing.

[4]  Xiaoxiong Xiong,et al.  Terra MODIS band 27 electronic crosstalk: cause, impact, and mitigation , 2011, Remote Sensing.

[5]  Xiaoxiong Xiong,et al.  Status of terra MODIS and aqua modis , 2003 .

[6]  Xiaoxiong Xiong,et al.  An overview of the Earth Observing System MODIS instrument and associated data systems performance , 2002, IEEE International Geoscience and Remote Sensing Symposium.

[7]  Brian Wenny,et al.  Terra MODIS Band 27 Electronic Crosstalk Effect and Its Removal , 2014, IEEE Transactions on Geoscience and Remote Sensing.

[8]  Aisheng Wu,et al.  Statistical analysis of the electronic crosstalk correction in Terra MODIS Band 27 , 2014, Optics & Photonics - Optical Engineering + Applications.

[9]  J. Sun,et al.  Terra MODIS band 2 electronic crosstalk: cause, impact, and mitigation , 2010, Remote Sensing.

[10]  Yonghong Li,et al.  Evaluation of Radiometric Improvements With Electronic Crosstalk Correction for Terra MODIS Band 27 , 2014, IEEE Transactions on Geoscience and Remote Sensing.

[11]  Amit Angal,et al.  Time-Dependent Response Versus Scan Angle for MODIS Reflective Solar Bands , 2014, IEEE Transactions on Geoscience and Remote Sensing.

[12]  Xiaoxiong Xiong,et al.  Investigation of the Electronic Crosstalk in Terra MODIS Band 28 , 2015, IEEE Transactions on Geoscience and Remote Sensing.