Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H(-) populations for various filter field strengths and pressures. Enhanced H(-) population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H(-) sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.
[1]
M. Bacal,et al.
Negative hydrogen ion production mechanisms
,
2015
.
[2]
Gon-Ho Kim,et al.
Global model analysis of negative ion generation in low-pressure inductively coupled hydrogen plasmas with bi-Maxwellian electron energy distributions
,
2015
.
[3]
K. Chung,et al.
Effects of discharge chamber length on the negative ion generation in volume-produced negative hydrogen ion source.
,
2014,
The Review of scientific instruments.
[4]
K. Chung,et al.
Development of a novel radio-frequency negative hydrogen ion source in conically converging configuration.
,
2014,
The Review of scientific instruments.
[5]
S. Lishev,et al.
Plasma behaviour affected by a magnetic filter
,
2007
.
[6]
A. Lichtenberg,et al.
Principles of Plasma Discharges and Materials Processing: Lieberman/Plasma 2e
,
2005
.
[7]
Y. Hwang,et al.
Development of a negative hydrogen ion source for tandem proton accelerator using transformer couled plasma sources
,
2002
.
[8]
M. Sasao,et al.
H− laser photodetachment at 1064, 532, and 355 nm in plasma
,
1998
.
[9]
M. Rosenbluth,et al.
DIFFUSION OF CHARGED PARTICLES ACROSS A MAGNETIC FIELD
,
1956
.