Infrared Screening of Residential Buildings for Energy Audit Purposes: Results of a Field Test

In the European Union (EU), the building sector is responsible for approximately 40% of total energy consumption. The existing building stock is inefficient and can, and indeed must be retrofitted to address this issue. The practical implementation of the European strategies requires knowledge of the energy performance of existing buildings through energy audit techniques. Application of thermography in the fields of energy are very widespread, since, through such a non-invasive investigation, and through correct interpretation of infrared images, it is possible to highlight inefficiencies in buildings and related facilities. The paper shows and discusses the results of an infrared audit campaign on 14 existing buildings located in Milan Province (Italy) made in different construction periods and characterised, therefore, by different building technologies. The U-values obtained in an indirect way through the thermography of the opaque walls of the buildings investigated, were compared with the actual known values in order to verify the reliability of the method and the possible margin of error. The study indicated that the category of buildings in which the application of this method is sufficiently reliable is that of solid-mass structure buildings, the most widespread in Italy, whereas in the case of buildings whose external walls are insulated, the percentage of deviation is very high.

[1]  Akira Hoyano,et al.  Analysis of the sensible heat flux from the exterior surface of buildings using time sequential thermography , 1999 .

[2]  J. Palyvos A survey of wind convection coefficient correlations for building envelope energy systems’ modeling , 2008 .

[3]  Giuliano Dall'O',et al.  Comparison between predicted and actual energy performance for summer cooling in high-performance residential buildings in the Lombardy region (Italy) , 2012 .

[4]  A. Dimoudi,et al.  Investigation of urban microclimate parameters in an urban center , 2013 .

[5]  Soteris A. Kalogirou,et al.  Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes , 2011 .

[6]  Giuliano Dall'O' Green Energy Audit of Buildings - A Guide for a Sunstainable Energy Audit of Buildings , 2013 .

[7]  Constantinos A. Balaras,et al.  Infrared thermography for building diagnostics , 2002 .

[8]  S. Zorasa,et al.  Investigation of urban microclimate parameters in an urban center , 2013 .

[9]  Nathan Mendes,et al.  New external convective heat transfer coefficient correlations for isolated low-rise buildings , 2007 .

[10]  Rossano Albatici,et al.  Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site , 2010 .

[11]  Dias Haralambopoulos,et al.  Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography , 1998 .

[12]  D Caccavelli,et al.  TOBUS — a European diagnosis and decision-making tool for office building upgrading , 2002 .