Circulating power test setup for a PWM rectifier motor drive

Power converters burn-in test consumes large amount of energy, which increases the cost of testing, and certification, in medium and high power application. A simple test configuration to test a PWM rectifier induction motor drive, using a Doubly Fed Induction Machine (DFIM) to circulate power back to the grid for burn-in test is presented. The test configuration makes use of only one power electronic converter, which is the converter to be tested. The test method ensures soft synchronization of DFIM and Squirrel Cage Induction Machine (SCIM). A simple volt per hertz control of the drive is sufficient for conducting the test. To synchronize the DFIM with SCIM, the rotor terminal voltage of DFIM is measured and used as an indication of speed mismatch between DFIM and SCIM. The synchronization is done when the DFIM rotor voltage is at its minimum. Analysis of the DFIM characteristics confirms that such a test can be effectively performed with smooth start up and loading of the test setup. After synchronization is obtained, the speed command to SCIM is changed in order to load the setup in motoring or regenerative mode of operation. The experimental results are presented that validates the proposed test method.

[1]  Jian Tang,et al.  Unified power electronic load for burn-in test , 2009, 2009 IEEE 6th International Power Electronics and Motion Control Conference.

[2]  R. Ruth,et al.  Load bank elimination for UPS testing , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[3]  G. Narayanan,et al.  Vector control of three-phase AC/DC front-end converter , 2008 .

[4]  Xin Chen,et al.  Research on digital controlled converter for AC power electronics burn-in test with Energy Feedback , 2008, 2008 International Conference on Electrical Machines and Systems.

[5]  Ming-Tsung Tsai,et al.  Energy recycling for electrical AC power source burn-in test , 2000, IEEE Trans. Ind. Electron..

[6]  Takao Kawabata,et al.  Parallel processing inverter system , 1991 .

[7]  Chun-Yueh Huang,et al.  A study on the test of UPS by energy feedback method , 1991, 1991., IEEE International Sympoisum on Circuits and Systems.

[8]  R. Datta,et al.  Decoupled control of active and reactive power for a grid-connected doubly-fed wound rotor induction machine without position sensors , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).