Micro-optical force distribution sensing suitable for lump/artery detection

Surgeons performing robotic-assisted surgical tasks need to establish the density and constituency of hidden tissue structures using only surgical tools. This is possible by integrating a miniaturized sensor into the end-effectors of robotic surgical systems. In this present work, optical microsystems technology is utilized to develop a miniature force-distribution sensor that can be integrated into surgical end-effectors. The sensing principle of the sensor is based on the mechanism of splice coupling. Since the device is fully optical, the sensor is magnetic-resonance compatible and is also electrically passive. The experimental results performed on the developed sensor confirm its ability to measure the distributed force information. Such information is used to detect different tissue structures such as lumps, arteries, or ureters during robotic-assisted surgical tasks.

[1]  Cosme Furlong,et al.  A Miniature MRI-Compatible Fiber-optic Force Sensor Utilizing Fabry-Perot Interferometer , 2011 .

[2]  M. Packirisamy,et al.  Discretely Loaded Beam-Type Optical Fiber Tactile Sensor for Tissue Manipulation and Palpation in Minimally Invasive Robotic Surgery , 2012, IEEE Sensors Journal.

[3]  Ai Qun Liu,et al.  Advanced fiber optical switches using deep RIE (DRIE) fabrication , 2003 .

[4]  Robert D. Howe,et al.  A Robust Uniaxial Force Sensor for Minimally Invasive Surgery , 2010, IEEE Transactions on Biomedical Engineering.

[5]  Sanghyun Joung,et al.  A Force Measurement Device Using Optical Fiber for Surgical Tools - Basic Concept and Implementation - , 2011, J. Robotics Mechatronics.

[6]  Ron Kikinis,et al.  MR Compatibility of Mechatronic Devices: Design Criteria , 1999, MICCAI.

[7]  Kaspar Althoefer,et al.  MRI-Compatible Fiber-Optic Force Sensors for Catheterization Procedures , 2010, IEEE Sensors Journal.

[8]  S. Sokhanvar,et al.  MEMS Endoscopic Tactile Sensor: Toward In-Situ and In-Vivo Tissue Softness Characterization , 2009, IEEE Sensors Journal.

[9]  L.D. Seneviratne,et al.  State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery , 2008, IEEE Sensors Journal.

[10]  F. P. Wieringa,et al.  Optical fiber sensors for medical applications: practical engineering considerations , 2009 .

[11]  Javad Dargahi,et al.  A new MRI-compatible optical fiber tactile sensor for use in minimally invasive robotic surgery systems , 2010, European Workshop on Optical Fibre Sensors.

[12]  Warren S. Grundfest,et al.  A Multielement Tactile Feedback System for Robot-Assisted Minimally Invasive Surgery , 2009, IEEE Transactions on Haptics.

[13]  Catherine E. Lewis,et al.  Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery , 2009, IEEE Transactions on Haptics.

[14]  Karol Miller,et al.  MRI Guided Surgical Robot , 2001 .

[15]  Matteo Bianchi,et al.  Rendering Softness: Integration of Kinesthetic and Cutaneous Information in a Haptic Device , 2010, IEEE Transactions on Haptics.

[16]  Kaspar Althoefer,et al.  Tactile sensing for dexterous in-hand manipulation in robotics-A review , 2011 .

[17]  Israel Gannot,et al.  Optical Fibers and Sensors for Medical Applications , 2001 .

[18]  Paula Gomes,et al.  Surgical robotics: Reviewing the past, analysing the present, imagining the future , 2011 .

[19]  T. Makimoto,et al.  Analysis of splice loss in single-mode fibres using a Gaussian field approximation , 1979 .

[20]  Hao Su,et al.  Real-time MRI-guided needle placement robot with integrated fiber optic force sensing , 2011, 2011 IEEE International Conference on Robotics and Automation.

[21]  Kaspar Althoefer,et al.  Novel miniature MRI-compatible fiber-optic force sensor for cardiac catheterization procedures , 2010, 2010 IEEE International Conference on Robotics and Automation.

[22]  Javad Dargahi,et al.  High Sensitive Force Sensing Based on the Optical Fiber Coupling Loss , 2013 .

[23]  Javad Dargahi,et al.  Innovative optical microsystem for static and dynamic tissue diagnosis in minimally invasive surgical operations. , 2012, Journal of biomedical optics.

[24]  Kaspar Althoefer,et al.  Mathematical Modeling of Intensity-Modulated Bent-Tip Optical Fiber Displacement Sensors , 2010, IEEE Transactions on Instrumentation and Measurement.

[25]  Javad Dargahi,et al.  Graphical Rendering of Localized Lumps for MIS Applications , 2007 .