Closed-loop commutation control of an MRI-powered robot actuator

Actuators that are powered, imaged and controlled by Magnetic Resonance (MR) scanners offer the potential of inexpensively providing wireless control of MR-guided robots. Similar to traditional electric motors, the MR scanner acts as the stator and generates propulsive torques on an actuator rotor containing one or more ferrous particles. To generate maximum motor torque while avoiding instabilities and slippage, closed-loop control of the electromagnetic field gradients, i.e., commutation, is required. This paper proposes and demonstrates a method for commutation based on interleaving pulse sequences for rotor tracking and rotor propulsion. Fast rotor tracking is achieved by a new technique utilizing radio-frequency (RF) selective excitation of a properly located fiducial marker by the ferrous particle of the rotor. Optimal marker location is derived and demonstrated to provide accurate estimates of rotor angle. In addition, closed-loop commutation control is shown to increase motor torque and also to enable regulation of rotor angle.

[1]  Gábor Székely,et al.  MRI driven magnetic microswimmers , 2012, Biomedical microdevices.

[2]  Sylvain Martel,et al.  Adapting the clinical MRI software environment for real‐time navigation of an endovascular untethered ferromagnetic bead for future endovascular interventions , 2008, Magnetic resonance in medicine.

[3]  John M Pauly,et al.  Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles , 2005, Magnetic resonance in medicine.

[4]  D. Caleb Rucker,et al.  A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study , 2012, 2012 IEEE International Conference on Robotics and Automation.

[5]  Pierre E. Dupont,et al.  Tracking and position control of an MRI-powered needle-insertion robot , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  Sukho Park,et al.  Novel electromagnetic actuation system for three-dimensional locomotion and drilling of intravascular microrobot , 2010 .

[7]  Carsten Framme,et al.  Steerable Intravitreal Inserts for Drug Delivery: In Vitro and Ex Vivo Mobility Experiments , 2011, MICCAI.

[8]  Robert Trampel,et al.  Method for automatic localization of MR‐visible markers using morphological image processing and conventional pulse sequences: Feasibility for image‐guided procedures , 2007, Journal of magnetic resonance imaging : JMRI.

[9]  M. Moche,et al.  Simultaneous 3D localization of multiple MR-visible markers in fully reconstructed MR images: proof-of-concept for subsecond position tracking. , 2012, Magnetic Resonance Imaging.

[10]  Metin Sitti,et al.  Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope , 2012, IEEE Transactions on Robotics.

[11]  Kostas E. Bekris,et al.  Visual and force-feedback guidance for robot-assisted interventions in the beating heart with real-time MRI , 2012, 2012 IEEE International Conference on Robotics and Automation.

[12]  Pierre E. Dupont,et al.  MRI-powered actuators for robotic interventions , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[13]  P. Dario,et al.  Magnetic propulsion and ultrasound tracking of endovascular devices , 2012, Journal of Robotic Surgery.

[14]  Peter Kazanzides,et al.  Robotic needle guide for prostate brachytherapy: clinical testing of feasibility and performance. , 2011, Brachytherapy.

[15]  Zion Tsz Ho Tse,et al.  Prospective motion correction using tracking coils , 2013, Magnetic resonance in medicine.