Fabrication of a flexible penetrating microelectrode array for use on curved surfaces of neural tissues

Conventionally, invasive neural microelectrodes for recording neuronal signals or stimulating the nervous system have been fabricated based on silicon substrate mainly due to well-established manufacturing processes. However, these silicon-based microelectrode devices have an issue of mechanical stability caused by the absence of flexibility when implanted onto curved surfaces of tissues. In this paper, a flexible and penetrating microelectrode array, a hybrid structure composed of silicon and elastomer, was devised and fabricated by bulk micromachining technologies. The structure uses individual silicon needles as independent electrodes in a square array and polydimethysiloxane (PDMS) as a base to support the needles. The dimensions of the electrode array and the needles are adjustable, depending on the number of needles, the pitch between the needles and the targeted penetration depth of the neural tissue. For mechanical characterization, the adhesion between PDMS and silicon was evaluated and the flexibility and integrity of the fabricated structure were investigated through flexural test and insertion test. Also, the electrochemical impedance spectroscopy of the electrodes was measured. The results suggest that the proposed microelectrode array is promising for use in neuronal recording and stimulation over curved surfaces such as cortical surface and peripheral nerves with larger curvatures.

[1]  R. Normann,et al.  A Novel Method of Fabricating Convoluted Shaped Electrode Arrays for Neural and Retinal Prosthesis , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[2]  R. Normann,et al.  Wafer Level Processing of Silicon Arrays for Implantable Medical Devices , 2007, 2007 Proceedings 57th Electronic Components and Technology Conference.

[3]  J. Donoghue,et al.  Sensors for brain-computer interfaces , 2006, IEEE Engineering in Medicine and Biology Magazine.

[4]  T. Stieglitz,et al.  Characterization of parylene C as an encapsulation material for implanted neural prostheses. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[5]  R. Stein,et al.  Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes. , 2001, Journal of neurophysiology.

[6]  Wei Zhao,et al.  A Flexible Microneedle Electrode Array With Solid Silicon Needles , 2012, Journal of Microelectromechanical Systems.

[7]  Rajmohan Bhandari,et al.  A novel masking method for high aspect ratio penetrating microelectrode arrays , 2009 .

[8]  K. Wise,et al.  A 64-site multishank CMOS low-profile neural stimulating probe , 1996, IEEE J. Solid State Circuits.

[9]  Theodore W Berger,et al.  A cortical neural prosthesis for restoring and enhancing memory , 2011, Journal of neural engineering.

[10]  John D. Simeral,et al.  Computer cursor control by motor cortical signals in humans with tetraplegia , 2009, 2009 7th Asian Control Conference.

[11]  Richard A Normann,et al.  Technology Insight: future neuroprosthetic therapies for disorders of the nervous system , 2007, Nature Clinical Practice Neurology.

[12]  Silvestro Micera,et al.  In vivo interactions between tungsten microneedles and peripheral nerves. , 2012, Medical engineering & physics.

[13]  L. Rieth,et al.  Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[14]  K. Cheung,et al.  Characterization of postfabricated parylene C coatings inside PDMS microdevices , 2011 .

[15]  Marianna E. Ivanova,et al.  Evaluation of cortical visual prostheses microelectrode array function. Description of behavioral feline model , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[17]  Nicolas Y. Masse,et al.  Reach and grasp by people with tetraplegia using a neurally controlled robotic arm , 2012, Nature.

[18]  D.M. Taylor,et al.  Use of Intracortical Recordings to Control a Hand Neuroprosthesis , 2007, 2007 3rd International IEEE/EMBS Conference on Neural Engineering.

[19]  L. Miller,et al.  Restoration of grasp following paralysis through brain-controlled stimulation of muscles , 2012, Nature.

[20]  K. Wise,et al.  A low-profile three-dimensional neural stimulating array with on-chip current generation , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  G A Clark,et al.  Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays. , 2012, Journal of neural engineering.

[22]  A. Mata,et al.  Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems , 2005, Biomedical microdevices.

[23]  Sung Yang,et al.  Fabrication of PDMS through-holes using the MIMIC method and the surface treatment by atmospheric-pressure CH4/He RF plasma , 2011 .

[24]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[25]  E. Fetz,et al.  Direct control of paralyzed muscles by cortical neurons , 2008, Nature.

[26]  Hansjörg Scherberger,et al.  Neural control of motor prostheses , 2009, Current Opinion in Neurobiology.

[27]  Rajmohan Bhandari,et al.  Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films , 2009 .

[28]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[29]  K. E. Jones,et al.  A glass/silicon composite intracortical electrode array , 2006, Annals of Biomedical Engineering.

[30]  Byron M. Yu,et al.  A high-performance brain–computer interface , 2006, Nature.

[31]  F. Solzbacher,et al.  In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays , 2010, Biomedical materials.

[32]  Kin Fong Lei,et al.  Microfluidic channel fabrication by PDMS-interface bonding , 2006 .

[33]  Sandeep Negi,et al.  Wafer-scale fabrication of penetrating neural microelectrode arrays , 2010, Biomedical microdevices.

[34]  Hyun-Chool Shin,et al.  Asynchronous Decoding of Dexterous Finger Movements Using M1 Neurons , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[35]  Chou-Ching K. Lin,et al.  Transverse elasticity of rabbit sciatic nerves tested by in vitro compression , 2004 .

[36]  Eduardo Fernández,et al.  Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve , 2004, IEEE Transactions on Biomedical Engineering.

[37]  Jean Delbeke,et al.  Cuff electrode implantation around the sciatic nerve is associated with an upregulation of TNF-α and TGF-β1 , 2005, Journal of Neuroimmunology.