Iterative Off-Resonance and Signal Decay Estimation and Correction for Multi-Echo MRI

Signal dephasing due to field inhomogeneity and signal decay due to transverse relaxation lead to perturbations of the Fourier encoding commonly applied in magnetic resonance imaging. Hence, images acquired with long readouts suffer from artifacts such as blurring, distortion, and intensity variation. These artifacts can be removed in reconstruction, usually based on separately collected information in form of field and relaxation maps. In this work, a recently proposed gridding-based algorithm for off-resonance correction is extended to also address signal decay. It is integrated into a new fixed-point iteration, which permits the joint estimation of an image and field and relaxation maps from multi-echo acquisitions. This approach is then applied in simulations and in vivo experiments and demonstrated to improve both images and maps. The rapid convergence of the fixed-point iteration in combination with the efficient gridding-based correction promises to render the running time of such a joint estimation acceptable.

[1]  Dorin Comaniciu,et al.  Mean Shift: A Robust Approach Toward Feature Space Analysis , 2002, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  Y. Kadah,et al.  Algebraic reconstruction for magnetic resonance imaging under B/sub 0/ inhomogeneity , 1998, IEEE Transactions on Medical Imaging.

[3]  Jeffrey A. Fessler,et al.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities , 2003, IEEE Transactions on Medical Imaging.

[4]  Douglas C. Noll,et al.  Deblurring for non‐2D fourier transform magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[5]  A. Maeda,et al.  Reconstruction by weighted correlation for MRI with time-varying gradients. , 1988, IEEE transactions on medical imaging.

[6]  J Hennig,et al.  Functional Imaging by I0‐ and T2* ‐parameter mapping using multi‐image EPI , 1998, Magnetic resonance in medicine.

[7]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[8]  Hermann Schomberg,et al.  Off-resonance correction of MR images , 1999, IEEE Transactions on Medical Imaging.

[9]  Vladimir Rokhlin,et al.  Fast Fourier Transforms for Nonequispaced Data , 1993, SIAM J. Sci. Comput..

[10]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[11]  Douglas C Noll,et al.  Dynamic field map estimation using a spiral‐in/spiral‐out acquisition , 2004, Magnetic resonance in medicine.

[12]  Gabriele Steidl,et al.  Fast Fourier Transforms for Nonequispaced Data: A Tutorial , 2001 .

[13]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[14]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[15]  P. Boesiger,et al.  Iterative B0 and T2 * Correction for Radial Multi-Gradient-Echo Imaging , 2004 .

[16]  Donald B. Twieg,et al.  Iterative reconstruction of single-shot spiral MRI with off resonance , 1999, IEEE Transactions on Medical Imaging.

[17]  Jeffrey A. Fessler,et al.  Simultaneous estimation of I,,, Rz*, and field map using a multi-echo spiral acquisition , 2002 .

[18]  A Macovski,et al.  Multifrequency interpolation for fast off‐resonance correction , 1997, Magnetic resonance in medicine.

[19]  R. Hoge,et al.  Density compensation functions for spiral MRI , 1997, Magnetic resonance in medicine.

[20]  E Moser,et al.  Functional MRI of the human motor cortex using single-shot, multiple gradient-echo spiral imaging. , 1999, Magnetic resonance imaging.

[21]  Kevin M Koch,et al.  Sample-specific diamagnetic and paramagnetic passive shimming. , 2006, Journal of magnetic resonance.

[22]  Donald B Twieg Parsing local signal evolution directly from a single‐shot MRI signal: A new approach for fMRI , 2003, Magnetic resonance in medicine.

[23]  M. Hestenes,et al.  Methods of conjugate gradients for solving linear systems , 1952 .

[24]  Stefan Kunis,et al.  A Note on the Iterative MRI Reconstruction from Nonuniform k-Space Data , 2007, Int. J. Biomed. Imaging.

[25]  Gene H. Golub,et al.  Matrix computations , 1983 .

[26]  Tobias Knopp,et al.  Field Inhomogeneity Correction Based on Gridding Reconstruction for Magnetic Resonance Imaging , 2007, IEEE Transactions on Medical Imaging.