A thermophilic apoglucose dehydrogenase as nonconsuming glucose sensor.

Blood glucose is a clinically important analytes for diabetic health care. In this preliminary report we describe a protein biosensor for d-glucose based on a thermostable glucose dehydrogenase. The glucose dehydrogenase was noncovalently labeled with 8-anilino-1-naphthalene sulfonic acid (ANS). The ANS-labeled enzyme displayed an approximate 25% decrease in emission intensity upon binding glucose. This decrease can be used to measure the glucose concentration. Our results suggest that enzymes which use glucose as their substrate can be used as reversible and nonconsuming glucose sensors in the absence of required cofactors. Moreover, the possibility of using inactive apoenzymes for a reversible sensor greatly expands the range of proteins which can be used as sensors, not only for glucose, but for a wide variety of biochemically relevant analytes.

[1]  J. Schultz,et al.  Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites , 1982, Diabetes Care.

[2]  W. March,et al.  Ocular glucose sensor. , 1982, Transactions - American Society for Artificial Internal Organs.

[3]  J. Lakowicz,et al.  Polarization sensing with visual detection. , 1999, Analytical chemistry.

[4]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.

[5]  J. Lakowicz,et al.  beta-glycosidase from the hyperthermophilic archaeon Sulfolobus solfataricus: structure and activity in the presence of alcohols. , 1999, Journal of biochemistry.

[6]  M Rossi,et al.  The fluorescence emission of the apo-glucose oxidase from Aspergillus niger as probe to estimate glucose concentrations. , 1999, Biochemical and biophysical research communications.

[7]  E. V. Thomas,et al.  Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation. , 1992, Clinical chemistry.

[8]  P Aldhous,et al.  Race quickens for non-stick blood monitoring technology. , 1992, Science.

[9]  S. d'Auria,et al.  Effects of temperature and SDS on the structure of beta-glycosidase from the thermophilic archaeon Sulfolobus solfataricus. , 1997, The Biochemical journal.

[10]  G. Weber Polarization of the fluorescence of macromolecules. II. Fluorescent conjugates of ovalbumin and bovine serum albumin. , 1952, The Biochemical journal.

[11]  D. Hough,et al.  Purification and characterization of glucose dehydrogenase from the thermoacidophilic archaebacterium Thermoplasma acidophilum. , 1989, The Biochemical journal.

[12]  J. Lakowicz,et al.  Anisotropy-based sensing with reference fluorophores. , 1999, Analytical biochemistry.

[13]  I Gryczynski,et al.  Glucose sensor for low-cost lifetime-based sensing using a genetically engineered protein. , 1999, Analytical biochemistry.

[14]  J. Schultz,et al.  Fiber-optic biosensors based on fluorescence energy transfer. , 1988, Talanta.

[15]  M. N. Gupta Thermostability of enzymes , 1993 .

[16]  J. Lakowicz Topics in fluorescence spectroscopy , 2002 .

[17]  V. V. Mozhaev,et al.  Structure-stability relationships in proteins: a guide to approaches to stabilizing enzymes , 1990 .

[18]  J. Lakowicz,et al.  The β-glycosidase from the hyperthermophilic archaeon Sulfolobus solfataricus: enzyme activity and conformational dynamics at temperatures above 100°C , 1999 .

[19]  J. Slavik,et al.  Anilinonaphthalene sulfonate as a probe of membrane composition and function. , 1982, Biochimica et biophysica acta.

[20]  W. March,et al.  Noninvasive Glucose Monitoring of the Aqueous Humor of the Eye: Part I. Measurement of Very Small Optical Rotations , 1982, Diabetes Care.