Assessing ventilation system performance in isolation rooms

In this paper numerical transient simulations were used to investigate the air flow patterns, distribution and velocity, and the particulate dispersion inside an existing typical hospitalization room equipped with an advanced Heating Ventilation Air Conditioning (HVAC), with Variable Air Volume (VAV) primary air system designed for immune-suppressed patients never modelled before. The three-dimensional models of the room consider different, most typical, positions of the patients. Results indicate the best conditions for the high induction air inlet diffuser and the scheme of pressures imposed in the room to provide the effective means of controlling flows containing virus droplets. We believe that our work exemplifies the usefulness of numerical investigations of HVAC performances in real situations and provides important recommendations towards disease control and careful design and optimization of ventilation in hospital settings.

[1]  L. Meyers Contact network epidemiology: Bond percolation applied to infectious disease prediction and control , 2006 .

[2]  Angui Li,et al.  The effect of air-conditioning parameters and deposition dust on microbial growth in supply air ducts , 2010 .

[3]  Peter C Raynor,et al.  Background culturable bacteria aerosol in two large public buildings using HVAC filters as long term, passive, high-volume air samplers. , 2008, Journal of environmental monitoring : JEM.

[4]  Tiina Reponen,et al.  Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation. , 2007, Environmental science & technology.

[5]  J. Lafitte,et al.  Peptides of human bronchial mucus glycoproteins. Size determination by electron microscopy and by biosynthetic experiments. , 1987, The Biochemical journal.

[6]  Bin Zhao,et al.  How Many Airborne Particles Emitted from a Nurse will Reach the Breathing Zone/Body Surface of the Patient in ISO Class-5 Single-Bed Hospital Protective Environments?—A Numerical Analysis , 2009 .

[7]  Constantinos A. Balaras,et al.  Indoor environmental quality in Hellenic hospital operating rooms , 2009 .

[8]  C. Méndez,et al.  Optimization of a hospital room by means of CFD for more efficient ventilation , 2008 .

[9]  Adolfo García-Sastre,et al.  The guinea pig as a transmission model for human influenza viruses. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[10]  O. Diekmann Mathematical Epidemiology of Infectious Diseases , 1996 .

[11]  Charles P Gerba,et al.  The occurrence of influenza A virus on household and day care center fomites. , 2005, The Journal of infection.

[12]  J T Walker,et al.  Hospital and community acquired infection and the built environment – design and testing of infection control rooms , 2007, Journal of Hospital Infection.

[13]  Raymond Tellier,et al.  Review of Aerosol Transmission of Influenza A Virus , 2006, Emerging infectious diseases.

[14]  Michael Soper Pandemic ready. HVAC systems for worst-case scenarios. , 2008, Health facilities management.

[15]  R. Mikolajczyk,et al.  Social Contacts and Mixing Patterns Relevant to the Spread of Infectious Diseases , 2008, PLoS medicine.

[16]  Shih-Cheng Hu,et al.  An experimental study on ventilation efficiency of isolation room , 2009 .

[17]  Peter C Raynor,et al.  Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters. , 2006, Journal of environmental monitoring : JEM.

[18]  Michael P. Atkinson,et al.  Quantifying the Routes of Transmission for Pandemic Influenza , 2008, Bulletin of mathematical biology.

[19]  Laura Rygielski,et al.  Creating comfort. Nine considerations for selecting the right hospital HVAC system. , 2007, Health facilities management.

[20]  Mark Nicas,et al.  An Integrated Model of Infection Risk in a Health‐Care Environment , 2006, Risk analysis : an official publication of the Society for Risk Analysis.

[21]  Jinkyun Cho,et al.  The predictions of infection risk of indoor airborne transmission of diseases in high-rise hospitals: Tracer gas simulation , 2010 .

[22]  Irene Martini,et al.  Methodology developed for the energy-productive diagnosis and evaluation in health buildings , 2007 .

[23]  D. Patnayak,et al.  Survival of Two Avian Respiratory Viruses on Porous and Nonporous Surfaces , 2006, Avian diseases.

[24]  Ruey-Jen Yang,et al.  Virus diffusion in isolation rooms , 2005, Journal of Hospital Infection.

[25]  Frank Thiele,et al.  Flow of microorganisms in a hospital stair shaft — Full-scale measurements and mathematical model , 1986 .

[26]  C. P. Yu,et al.  Total and regional deposition of inhaled aerosols in humans , 1983 .

[27]  C. W. Keevil,et al.  Inactivation of Influenza A Virus on Copper versus Stainless Steel Surfaces , 2007, Applied and Environmental Microbiology.

[28]  J. Zimmerman,et al.  A method to provide improved dose–response estimates for airborne pathogens in animals: An example using porcine reproductive and respiratory syndrome virus , 2008, Veterinary Microbiology.

[29]  E. Cunningham On the Velocity of Steady Fall of Spherical Particles through Fluid Medium , 1910 .

[30]  E. L. Galson,et al.  Hospital sepsis control and TB transmission , 1995 .

[31]  I. Eames,et al.  Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises , 2006, Journal of Hospital Infection.