Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf

Abstract This paper presents the results of an experimental investigation in which the performance of the low-pressure fluids R134a and R1234yf was compared between a two-phase ejector cycle and expansion valve cycles. An alternate two-phase ejector cycle, in which the pressure lift provided by the ejector was utilized in order to provide multiple evaporation temperatures, was constructed and tested. The experimental results show that ejectors designed for low-pressure fluids were able to achieve similar but lower work recovery efficiencies compared to CO2 ejectors. When compared to a two evaporation temperature expansion valve cycle, the ejector cycle showed maximum COP improvements of 12% with R1234yf and 8% with R134a. When compared to a single evaporation temperature expansion valve cycle, the ejector cycle showed maximum COP improvements of 6% with R1234yf and 5% with R134a. The effect of evaporator design on ejector cycle COP improvement was also demonstrated experimentally.

[1]  Juergen Koehler,et al.  Experimental investigation of the COP improvement of a refrigeration cycle by use of an ejector , 2012 .

[2]  Somchai Wongwises,et al.  Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device , 2004 .

[3]  Masafumi Nakagawa,et al.  Experimental analysis on the effect of internal heat exchanger in transcritical CO2 refrigeration cycle with two-phase ejector. , 2011 .

[4]  Mika Gocho,et al.  Evaporator with Integrated Ejector for Automotive Cabin Cooling , 2012 .

[5]  F. Liu,et al.  Performance enhancement of CO2 air conditioner with a controllable ejector , 2012 .

[6]  Neal Lawrence,et al.  Theoretical and practical comparison of two-phase ejector refrigeration cycles including First and Second Law analysis , 2013 .

[7]  Trond Andresen,et al.  Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump , 2012 .

[8]  N. Lawrence Analytical and experimental investigation of two-phase ejector cycles using low-pressure refrigerants , 2013 .

[9]  Alan A. Kornhauser,et al.  The Use of an Ejector as a Refrigerant Expander , 1990 .

[10]  Alan A. Kornhauser,et al.  Performance tests of a two phase ejector , 1995 .

[11]  Min-Soo Kim,et al.  Experimental study on the improvement of CO2 air conditioning system performance using an ejector , 2011 .

[12]  Predrag Stojan Hrnjak,et al.  Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation , 2008 .

[13]  Masafumi Nakagawa,et al.  Performance of Two Phase Ejector in Refrigeration Cycle. , 1998 .

[14]  Predrag Stojan Hrnjak,et al.  Flash gas bypass for improving the performance of transcritical R744 systems that use microchannel evaporators , 2004 .

[15]  Neal Lawrence,et al.  Experimental and Analytical Investigation of Automotive Ejector Air- Conditioning Cycles Using Low-Pressure Refrigerants , 2012 .

[16]  Masafumi Nakagawa,et al.  Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchanger , 2011 .