Characteristics of Firebrands Collected from Actual Urban Fires

The characteristics of firebrands collected from a recent urban fire in Japan are described. Specifically, this fire broke out from a Chinese restaurant in Itoigawa-city, Niigata, Japan on December 22nd 2016. On the day of the fire, strong winds resulted in rapid fire spread. With the presence of an average wind speed of 9 m/s, the fire quickly spread, resulting in the damage of 147 structures, with 120 of 147 destroyed. The fire was extinguished more than 30 h later. During the fire, firebrands were observed and 10 spot fires were reported. After the fire, investigations were performed and firebrands were collected from the burn site. The size and the mass of firebrands were measured and compared with the available literature data. It was observed that more than 60% of the collected firebrands had less than 0.10 g mass and 2.0 cm2 projected area and the size and the mass of firebrands were independent of the location. The size and the mass of firebrands from this fire were similar to those from another urban fire under similar wind speed and were also compared to those produced from a firebrand generator. The firebrand data set presented here provided valuable insights into how firebrands are generated from structures in actual urban fires. Finally, the description on how a firebrand generator may be used to produce firebrands similar to urban fires yields an important advancement to begin to study such complex phenomena in the laboratory.

[1]  Yoshihiko Hayashi,et al.  Real-Scale Fire Wind Tunnel Experiment on Generation of Firebrands from a House on Fire , 2004 .

[2]  Samuel L. Manzello,et al.  Firebrand Generation Data Obtained from a Full Scale Structure Burn | NIST , 2011 .

[3]  Yuji Hasemi,et al.  Firebrand deposition and measurements of collected firebrands generated and transported from a full-Scale burn test using a large wooden building , 2014 .

[4]  Sayaka Suzuki,et al.  Firebrand Production from Building Components Fitted with Siding Treatments. , 2016, Fire safety journal.

[5]  Samuel L. Manzello,et al.  Enabling the Investigation of Structure Vulnerabilities to Wind- Driven Firebrand Showers in Wildland-Urban Interface (WUI) Fires , 2014 .

[6]  Samuel L. Manzello,et al.  Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire , 2014 .

[7]  Carlos Sánchez Tarifa,et al.  On the flight pahts and lifetimes of burning particles of wood , 1965 .

[8]  Samuel L. Manzello,et al.  Firebrands generated from a full-scale structure burning under well-controlled laboratory conditions , 2014 .

[9]  Yukio Tamura,et al.  Tachikawa number: A proposal , 2006 .

[10]  Yoshifumi Ohmiya,et al.  An Investigation on the Distribution of Fire Brands and Spot Fires Due to a Hotel Fire , 2000 .

[11]  Samuel L. Manzello,et al.  The size and mass distribution of firebrands collected from ignited building components exposed to wind , 2013 .

[12]  Haihui Wang Analysis on Downwind Distribution of Firebrands Sourced from a Wildland Fire , 2011 .

[13]  Sayaka Suzuki,et al.  Generating Wind-Driven Firebrand Showers Characteristic of Burning Structures. , 2017, Proceedings of the Combustion Institute. International Symposium on Combustion.

[14]  Derek McNamara,et al.  Case Study of a Community Affected by the Waldo Fire - Event Timeline and Defensive Actions , 2015 .

[15]  I. K. Knight The Design and Construction of a Vertical Wind Tunnel for the Study of Untethered Firebrands in Flight , 2001 .