Method to improve passive fit of frameworks on implant-supported prostheses: An in vitro study.

STATEMENT OF PROBLEM The passivity of the superstructure to the abutments of implant-supported prostheses is necessary for implant-prosthesis success. Improvements are needed in the methods of verifying passivity. PURPOSE The purpose of this in vitro study was to evaluate an inexpensive, easy to make, and user-friendly device to verify the position of the implant abutment replicas of the definitive cast and to avoid framework misfit before fabrication. MATERIAL AND METHODS Eighty stone devices were constructed on a metal base for the in vitro tests. The horizontal, vertical, and angled positions of the implant replicas were created to simulate misfits. The devices were fitted on the abutment replicas, and their ability to identify misfits was evaluated. A statistical analysis was not indicated, because the probability of fracture of the stone devices was 0 or 1. Two mathematical models were built using computer-aided design software (SolidWorks Premium; Dassault Systèmes SolidWorks Corp), and the finite element method was used (Ansys; ANSYS Inc) to simulate the structural behavior of 2 implant configurations (4 and 6 implants). RESULTS Horizontal misfits of 150 μm, vertical misfits of 50 μm, and angled misfits of 1 degree were detected during the in vitro tests. Different loads and bone quality in the mathematical models did not change stress in the prosthesis configurations on 4 or 6 implants in a relevant way. CONCLUSIONS The fabricated device was easily able to detect the misfits in accordance with the defined parameters.

[1]  Marco Antonio Bottino,et al.  A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks. , 2014, The Journal of prosthetic dentistry.

[2]  B R Lang,et al.  Periotest method: implant-supported framework fit evaluation in vivo. , 1998, The Journal of prosthetic dentistry.

[3]  O C Tebrock,et al.  A measurement of torque values obtained with hand-held drivers in a simulated clinical setting. , 1993, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[4]  C. Manzella,et al.  Verify the position of implants in master casts for implant-supported prostheses with stone devices , 2007 .

[5]  J I Nicholls,et al.  The measurement of distortion: mathematical considerations. , 1978, The Journal of prosthetic dentistry.

[6]  E J Rasmussen,et al.  Alternative prosthodontic technique for tissue-integrated prostheses. , 1987, The Journal of prosthetic dentistry.

[7]  A. Natali,et al.  Interaction phenomena between oral implants and bone tissue in single and multiple implant frames under occlusal loads and misfit conditions: A numerical approach. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[8]  Matthias Karl,et al.  Bone loading caused by different types of misfits of implant-supported fixed dental prostheses: a three-dimensional finite element analysis based on experimental results. , 2010, The International journal of oral & maxillofacial implants.

[9]  Steven E Eckert,et al.  Cyclic loading of implant-supported prostheses: changes in component fit over time. , 2003, The Journal of prosthetic dentistry.

[10]  A. Carr,et al.  Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings. , 1999, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[11]  G E Goll,et al.  Production of accurately fitting full-arch implant frameworks: Part I--Clinical procedures. , 1991, The Journal of prosthetic dentistry.

[12]  J I Nicholls,et al.  Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. , 1993, The International journal of prosthodontics.

[13]  Neil L. Starr,et al.  Clinical Methods for Evaluating Implant Framework Fit , 1999 .

[14]  N S Javid,et al.  Prefabricated acrylic resin bars for splinting implant transfer copings. , 2000, The Journal of prosthetic dentistry.

[15]  R C Knudson,et al.  Implant transfer coping verification jig. , 1989, The Journal of prosthetic dentistry.

[16]  M. Çehreli,et al.  The Significance Of Passive Framework Fit In Implant Prosthodontics: Current Status , 2001, Implant Dentistry.

[17]  B R Lang,et al.  Fit of implant frameworks fabricated by different techniques. , 1997, The Journal of prosthetic dentistry.

[18]  J I Nicholls,et al.  Distortion in dental soldering as affected by gap distance. , 1980, The Journal of prosthetic dentistry.

[19]  S M Morgano,et al.  Use of aluminum strips to fabricate verification jig for an implant-supported fixed partial denture. , 1998, The Journal of prosthetic dentistry.

[20]  Mansour Al-Ajmi,et al.  A positioning jig to verify the accuracy of implant abutments. , 2002, The Journal of prosthetic dentistry.

[21]  J W McCartney,et al.  Segmental framework matrix: master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses. , 1994, The Journal of prosthetic dentistry.

[22]  J I Nicholls,et al.  Tolerance measurements of various implant components. , 1997, The International journal of oral & maxillofacial implants.

[23]  F. D. das Neves,et al.  Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses. , 2015, The Journal of prosthetic dentistry.

[24]  G J Ziebert,et al.  Accuracy of one-piece castings, preceramic and postceramic soldering. , 1986, The Journal of prosthetic dentistry.

[25]  Chong-Hyun Han,et al.  Displacement of implant components from impressions to definitive casts. , 2006, The International journal of oral & maxillofacial implants.

[26]  N Stern,et al.  Effect of impression materials and techniques on the marginal fit of metal castings. , 1994, The Journal of prosthetic dentistry.

[27]  J I Nicholls The measurement of distortion: theoretical considerations. , 1977, The Journal of prosthetic dentistry.

[28]  T. Jemt Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[29]  J I Nicholls,et al.  Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. , 1993, The International journal of prosthodontics.

[30]  J I Nicholls,et al.  An evaluation of impression techniques for osseointegrated implants. , 1990, The Journal of prosthetic dentistry.

[31]  P P Binon,et al.  The effect of eliminating implant/abutment rotational misfit on screw joint stability. , 1996, The International journal of prosthodontics.

[33]  S A Aquilino,et al.  Evaluation of three impression techniques for osseointegrated oral implants. , 1993, The Journal of prosthetic dentistry.

[35]  C. Feng,et al.  The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture. , 2012, Clinical implant dentistry and related research.

[36]  R L Schneider,et al.  Fabricating low-fusing metal casts for more accurate implant prosthodontics. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[37]  D. Curtis,et al.  The effect of casting procedures on rotational misfit in castable abutments. , 2007, The International journal of oral & maxillofacial implants.

[38]  P J Henry,et al.  An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. , 1987, The Journal of prosthetic dentistry.

[39]  D Assif,et al.  Comparative accuracy of implant impression procedures. , 1992, The International journal of periodontics & restorative dentistry.