Optimal Automatic Generation Control of Asynchronous Power Systems Using Output Feedback Control Strategy with Dynamic Participation of Wind Turbines

Abstract—This article presents the design of optimal output feedback automatic generation control regulators for an interconnected power system with dynamic participation of doubly fed induction generator based wind turbines. The power systems consist of plants with hydro-thermal turbines and are interconnected via parallel AC/DC links. Efforts have been made to propose optimal automatic generation control regulators based on feedback of output state variables, which are easily accessible and available for the measurement. The designed optimal output feedback automatic generation control regulators are implemented, and the system dynamic responses for various system states are obtained considering 1% load perturbation in one of the areas. The dynamic performance is compared with that obtained with optimal automatic generation control regulators designed using full state vector feedback. The pattern of closed-loop eigenvalues is also determined to test the system stability.

[1]  Takashi Hiyama Optimisation of discrete-type load-frequency regulators considering generation-rate constraints , 1982 .

[2]  Charles E. Fosha,et al.  Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems , 1970 .

[3]  H. Banakar,et al.  Kinetic Energy of Wind-Turbine Generators for System Frequency Support , 2009, IEEE Transactions on Power Systems.

[4]  J.A.P. Lopes,et al.  Participation of Doubly Fed Induction Wind Generators in System Frequency Regulation , 2007, IEEE Transactions on Power Systems.

[5]  J. Nanda,et al.  Application of optimal control strategy to automatic generation control of a hydrothermal system , 1988 .

[6]  H. Horisberger,et al.  Solution of the optimal constant output feedback problem by conjugate gradients , 1974 .

[7]  J.A. Ferreira,et al.  Wind turbines emulating inertia and supporting primary frequency control , 2006, IEEE Transactions on Power Systems.

[8]  Richard Bellman,et al.  Introduction to Matrix Analysis , 1972 .

[9]  J. Nanda,et al.  Some new findings on automatic generation control of an interconnected hydrothermal system with conventional controllers , 2006, IEEE Transactions on Energy Conversion.

[10]  J. Nanda,et al.  Transactions on Power Apparatus and Systems , Vol . PAS-1 O 0 , No . 5 , May 1981 SAMPLED-DATA AUTOMATIC GENERATION CONTROL OF INTERCONNECTED REHEAT THERMAL SYSTEMS CONSIDERING GENERATION RATE CONSTRAINTS , 2006 .

[11]  Prabhat Kumar,et al.  Sub-optimal Automatic Generation Control of Interconnected Power System Using Output Vector Feedback Control Strategy , 2012 .

[12]  Ibraheem,et al.  Effect of parameter uncertainties on dynamic performance of an interconnected power system with AC/DC links , 2005 .

[13]  C. M. Liaw,et al.  On the design of an optimal automatic generation controller for interconnected power systems , 1993 .

[14]  Michael Athans,et al.  The Matrix Minimum Principle , 1967, Inf. Control..

[15]  Charles E. Fosha,et al.  The Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory , 1970 .

[16]  Ranjit Roy,et al.  Load frequency control of interconnected restructured power system along with DFIG and coordinated operation of TCPS-SMES , 2010, 2010 Joint International Conference on Power Electronics, Drives and Energy Systems & 2010 Power India.

[17]  J.M. Mauricio,et al.  Frequency Regulation Contribution Through Variable-Speed Wind Energy Conversion Systems , 2009, IEEE Transactions on Power Systems.

[18]  J. L. Willems Sensitivity Analysis of the Optimum Performance of Conventional Load-Frequency Control , 1974 .

[19]  R. Kosut Suboptimal control of linear time-invariant systems subject to control structure constraints , 1970 .

[20]  P. Smith Numerical solution of the matrix equation AX + XAT+ B = 0 , 1971 .

[21]  P. Sarachik,et al.  The design of optimal compensators for linear constant systems with inaccessible states , 1973 .

[22]  Tai Nengling,et al.  Review of contribution to frequency control through variable speed wind turbine , 2011 .

[23]  Prabhat Kumar,et al.  Optimal Automatic Generation Control of Interconnected Power System with Asynchronous Tie-lines under Deregulated Environment , 2012 .

[24]  Milan Calovic,et al.  Linear Regulator Design for a Load and Frequency Control , 1972 .

[25]  Takashi Yahagi Optimal output feedback control with reduced performance index sensitivity , 1977 .

[26]  N. Jenkins,et al.  Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency , 2004, IEEE Transactions on Energy Conversion.