Dynamic three-dimensional freehand echocardiography using raw digital ultrasound data.

In this paper, we present a new method for simple acquisition of dynamic three-dimensional (3-D) ultrasound data. We used a magnetic position sensor device attached to the ultrasound probe for spatial location of the probe, which was slowly tilted in the transthoracic scanning position. The 3-D data were recorded in 10-20 s, and the analysis was performed on an external PC within 2 min after transferring the raw digital ultrasound data directly from the scanner. The spatial and temporal resolutions of the reconstruction were evaluated, and were superior to video-based 3-D systems. Examples of volume reconstructions with better than 7 ms temporal resolution are given. The raw data with Doppler measurements were used to reconstruct both blood and tissue velocity volumes. The velocity estimates were available for optimal visualization and for quantitative analysis. The freehand data reconstruction accuracy was tested by volume estimation of balloon phantoms, giving high correlation with true volumes. Results show in vivo 3-D reconstruction and visualization of mitral and aortic valve morphology and blood flow, and myocardial tissue velocity. We conclude that it was possible to construct multimodality 3-D data in a limited region of the human heart within one respiration cycle, with reconstruction errors smaller than the resolution of the original ultrasound beam, and with a temporal resolution of up to 150 frames per second.

[1]  E Merz,et al.  Volume scanning in the evaluation of fetal malformations: a new dimension in prenatal diagnosis , 1995, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[2]  M. Yamagishi,et al.  New method for evaluating left ventricular wall motion by color-coded tissue Doppler imaging: in vitro and in vivo studies. , 1995, Journal of the American College of Cardiology.

[3]  R W Prager,et al.  Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.

[4]  D. Leotta,et al.  Performance of a miniature magnetic position sensor for three-dimensional ultrasound imaging. , 1997, Ultrasound in medicine & biology.

[5]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE Transactions on Sonics and Ultrasonics.

[6]  J. Waterton,et al.  Three-dimensional freehand ultrasound: image reconstruction and volume analysis. , 1997, Ultrasound in medicine & biology.

[7]  M Jones,et al.  Real-time three-dimensional echocardiography for determining right ventricular stroke volume in an animal model of chronic right ventricular volume overload. , 1998, Circulation.

[8]  A Salustri,et al.  Transthoracic three-dimensional echocardiography in adult patients with congenital heart disease. , 1995, Journal of the American College of Cardiology.

[9]  O. Gilja,et al.  In vivo comparison of 3D ultrasonography and magnetic resonance imaging in volume estimation of human kidneys. , 1995, Ultrasound in medicine & biology.

[10]  F J Ten Cate,et al.  Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography. , 1996, Journal of the American College of Cardiology.

[11]  J. Seward,et al.  Three-dimensional reconstruction of color Doppler jets in the human heart. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  W. Moritz,et al.  An Ultrasonic Technique for Imaging the Ventricle in Three Dimensions and Calculating Its Volume , 1983, IEEE Transactions on Biomedical Engineering.

[13]  A Fenster,et al.  Three-dimensional colour Doppler imaging. , 1993, Ultrasound in medicine & biology.

[14]  O. Gilja,et al.  In vitro evaluation of three-dimensional ultrasonography in volume estimation of abdominal organs. , 1994, Ultrasound in medicine & biology.

[15]  Odd Helge Gilja,et al.  A practical method for estimating enclosed volumes using 3D ultrasound , 1996 .

[16]  Hans Torp,et al.  In-vivo three-dimensional ultrasound reconstructions of embryos and early fetuses , 1998, The Lancet.

[17]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  D. King,et al.  Left ventricular volume and endocardial surface area by three-dimensional echocardiography: comparison with two-dimensional echocardiography and nuclear magnetic resonance imaging in normal subjects. , 1993, Journal of the American College of Cardiology.

[19]  E A Geiser,et al.  Dynamic three-dimensional echocardiographic reconstruction of the intact human left ventricle: technique and initial observations in patients. , 1982, American heart journal.

[20]  D F Leotta,et al.  Quantitative three-dimensional echocardiography by rapid imaging from multiple transthoracic windows: in vitro validation and initial in vivo studies. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[21]  A. Støylen,et al.  Real-time strain rate imaging of the left ventricle by ultrasound. , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[22]  S. Hughes,et al.  Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor. , 1996, Ultrasound in medicine & biology.

[23]  Bjørn Olstad,et al.  Volume rendering of 3D medical ultrasound data using direct feature mapping , 1994, IEEE Trans. Medical Imaging.

[24]  D. King,et al.  Three‐dimensional spatial registration and interactive display of position and orientation of real‐time ultrasound images. , 1990, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[25]  G Bashein,et al.  3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.