Artificial Urinary Sphincter Cuff Size Predicts Outcome in Male Patients Treated for Stress Incontinence: Results of a Large Central European Multicenter Cohort Study

Purpose The aim was to study the correlation between cuff size and outcome after implantation of an AMS 800 artificial urinary sphincter. Methods A total of 473 male patients with an AMS 800 sphincter implanted between 2012 and 2014 were analyzed in a retrospective multicenter cohort study performed as part of the Central European Debates on Male Incontinence (DOMINO) Project. Results Single cuffs were implanted in 54.5% and double cuffs in 45.5% of the patients. The cuffs used had a median circumference of 4.5 cm. Within a median follow of 18 months, urethral erosion occurred in 12.8% of the cases and was associated significantly more often with small cuff sizes (P<0.001). Multivariate analysis showed that, apart from cuff size (P=0.03), prior irradiation (P<0.001) and the penoscrotal approach (P=0.036) were associated with an increased erosion rate. Continence rate tended to be highest with median cuff sizes (4–5.5 cm). Conclusions Apart from irradiation and the penoscrotal approach, small cuff size is a risk factor for urethral erosion. Results are best with cuff sizes of 4.5–5.5 cm.

[1]  E. Haglind,et al.  Corrigendum re: "Urinary Incontinence and Erectile Dysfunction After Robotic Versus Open Radical Prostatectomy: A Prospective, Controlled, Nonrandomised Trial" [Eur Urol 2015;68:216-25]. , 2017, European urology.

[2]  J. Dominguez-escrig,et al.  Prospective follow‐up study of artificial urinary sphincter placement preserving the bulbospongiosus muscle , 2017, Neurourology and urodynamics.

[3]  W. Hellstrom,et al.  Device Survival after Primary Implantation of an Artificial Urinary Sphincter for Male Stress Urinary Incontinence , 2017, The Journal of urology.

[4]  D. Agarwal,et al.  Artificial urinary sphincter urethral erosions: Temporal patterns, management, and incidence of preventable erosions , 2017, Indian journal of urology : IJU : journal of the Urological Society of India.

[5]  C. Rosenbaum,et al.  Outcomes of single‐ vs double‐cuff artificial urinary sphincter insertion in low‐ and high‐risk profile male patients with severe stress urinary incontinence , 2016, BJU international.

[6]  L. Rangel,et al.  Artificial Urinary Sphincter Mechanical Failures-Is it Better to Replace the Entire Device or Just the Malfunctioning Component? , 2016, The Journal of urology.

[7]  B. Linder,et al.  Long-term Outcomes Following Artificial Urinary Sphincter Placement: An Analysis of 1082 Cases at Mayo Clinic. , 2015, Urology.

[8]  Stefan Carlsson,et al.  Urinary Incontinence and Erectile Dysfunction After Robotic Versus Open Radical Prostatectomy: A Prospective, Controlled, Nonrandomised Trial. , 2015, European urology.

[9]  C. Roehrborn,et al.  3.5 cm artificial urinary sphincter cuff erosion occurs predominantly in irradiated patients. , 2015, The Journal of urology.

[10]  S. Hudak,et al.  Decreasing need for artificial urinary sphincter revision surgery by precise cuff sizing in men with spongiosal atrophy. , 2014, The Journal of urology.

[11]  M. Drake,et al.  The artificial urinary sphincter after a quarter of a century: a critical systematic review of its use in male non-neurogenic incontinence. , 2013, European urology.

[12]  A. Vickers,et al.  The surgical learning curve for artificial urinary sphincter procedures compared to typical surgeon experience. , 2011, European urology.

[13]  S. Hudak,et al.  Impact of 3.5 cm artificial urinary sphincter cuff on primary and revision surgery for male stress urinary incontinence. , 2011, The Journal of urology.

[14]  P. Aliotta,et al.  New enhancements of the scrotal one-incision technique for placement of artificial urinary sphincter allow proximal cuff placement. , 2010, The journal of sexual medicine.

[15]  A. Morey,et al.  Correlation of penile and bulbospongiosus measurements: implications for artificial urinary sphincter cuff placement. , 2010, The Journal of urology.

[16]  G. Webster,et al.  Outcomes following erosions of the artificial urinary sphincter. , 2006, The Journal of urology.

[17]  G. Webster,et al.  Transcorporal artificial urinary sphincter cuff placement in cases requiring revision for erosion and urethral atrophy. , 2002, The Journal of urology.

[18]  Scott Fb The artificial urinary sphincter. Experience in adults. , 1989 .

[19]  Li Wang,et al.  Difference between urethral circumference and artificial urinary sphincter cuff size, and its effect on postoperative incontinence. , 2014, The Journal of urology.

[20]  M. Cleves,et al.  A multicenter study on the perineal versus penoscrotal approach for implantation of an artificial urinary sphincter: cuff size and control of male stress urinary incontinence. , 2009, The Journal of urology.

[21]  Mark B. Lyon,et al.  Long-term follow-up of single versus double cuff artificial urinary sphincter insertion for the treatment of severe postprostatectomy stress urinary incontinence. , 2008, Urology.

[22]  Steven K. Wilson,et al.  New surgical technique for sphincter urinary control system using upper transverse scrotal incision. , 2003, The Journal of urology.

[23]  F. B. Scott The artificial urinary sphincter. Experience in adults. , 1989, The Urologic clinics of North America.