Intramural Coronary Vasculature Prevents Transmural Radiofrequency Lesion Formation: Implications for Linear Ablation

Background—Blood flow near a radiofrequency (RF) lesion can reduce lesion size by convective cooling. It is unknown whether blood flow through small vasculature within an RF lesion can prevent transmural lesion formation. Methods and Results—In 40 rabbit right ventricle preparations, 2 epicardial RF lesions were created straddling a selectively perfused (0 to 12 mL/min) marginal artery (diameter, 0.34±0.1 mm). RF lesions were created at either 60°C or 80°C and delivered either sequentially or simultaneously. Conduction through the lesion area was measured. The lesions were analyzed histologically. At a perfusion rate of 0 mL/min, all RF lesions were transmural and without conduction. As little as 1 mL of flow through the artery during RF delivery could prevent transmural lesion formation by preserving a cuff of tissue along the length of the vessel. High-energy delivery (45 W) and very high tissue temperatures (93°C) were needed to overcome the protective effect of vascular perfusion at 12 mL/min. The volume of preserved myocardium was related to arterial perfusion rate, artery diameter, and lesion temperature but not to the sequence of RF delivery (sequential versus simultaneous). Conduction persisted through the RF lesion in 20 experiments. Conduction through the lesion was related to the arterial perfusion rate and volume or cross-sectional area of preserved myocardium. Conclusions—Flow through even small intramyocardial vessels can prevent transmural lesion formation and preserve conduction through an RF lesion. These findings may represent an unrecognized obstacle to the creation of linear RF lesions in the clinical setting.

[1]  I. McRury,et al.  The Effect of Ablation Sequence and Duration on Lesion Shape Using Rapidly Pulsed Radiofrequency Energy Through Multiple Electrodes , 2000, Journal of Interventional Cardiac Electrophysiology.

[2]  N. Saoudi,et al.  Radiofrequency catheter ablation of atrial flutter. Further insights into the various types of isthmus block: application to ablation during sinus rhythm. , 1996, Circulation.

[3]  D. Ross,et al.  The Effect of a Residual Isthmus of Surviving Tissue on Conduction after Linear Ablation in Atrial Myocardium , 2000, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing.

[4]  F. Marchlinski,et al.  Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. , 2000, Circulation.

[5]  FRACP Stuart P Thomas BMed,et al.  The Effect of a Residual Isthmus of Surviving Tissue on Conduction after Linear Ablation in Atrial Myocardium , 2004, Journal of Interventional Cardiac Electrophysiology.

[6]  J Clémenty,et al.  Mapping and ablation of left atrial flutters. , 2000, Circulation.

[7]  D D Watson,et al.  Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. , 1990, Circulation research.

[8]  M. Wood,et al.  Acute and Chronic Electrophysiologic Changes Surrounding Radiofrequency Lesions , 2002, Journal of cardiovascular electrophysiology.

[9]  Ottavio Alfieri,et al.  Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation Efficacy of an Anatomic Approach in a Large Cohort of Patients With Atrial Fibrillation , 2002 .

[10]  Hutchinson Mc A study of the artrial arteries in man. , 1978 .

[11]  A R Jayaweera,et al.  Effects of radiofrequency catheter ablation on regional myocardial blood flow. Possible mechanism for late electrophysiological outcome. , 1994, Circulation.

[12]  H. Calkins,et al.  A new system for catheter ablation of atrial fibrillation. , 1999, The American journal of cardiology.

[13]  M. Haissaguerre,et al.  Right and Left Atrial Radiofrequency Catheter Therapy of Paroxysmal Atrial Fibrillation , 1996, Journal of cardiovascular electrophysiology.

[14]  O. Alfieri,et al.  Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation: Efficacy of an Anatomic Approach in a Large Cohort of Patients With Atrial Fibrillation , 2001, Circulation.

[15]  W. Stevenson,et al.  Increasing catheter ablation lesion size by simultaneous application of radiofrequency current to two adjacent sites. , 1993, American heart journal.

[16]  R. Hauer,et al.  Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model. , 1998, Journal of the American College of Cardiology.

[17]  D. Haines,et al.  Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. , 1990, Circulation.

[18]  J. Svendsen,et al.  Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. , 1999, Circulation.