Overhead lines are known to emit audible noise during foul weather conditions. Audible noise phenomena depend largely on the OHL conductor’s surface gradient which is therefore also used in all equations for audible noise prediction. Various methods for the calculation of OHL surface gradients have been developed in the past. By using a realistic Indonesian tower design as an example, this contribution draws a comparison between surface gradient results obtained with several common calculation methods and with a finite element calculation. The investigated methods include the Maxwell Potential Coefficient Method, MARKT and MENGELE’s method and Charge Simulation Method. A software has been developed for the assessment of the charge simulation method which is also presented here. The comparisons show that even relatively simple methods yield reliable results. Furthermore, this paper investigates the validity of audible noise prediction equations for AC as well as DC OHL with four-conductor bundles. For that purpose, audible noise measurements were carried out in a high voltage laboratory under realistic weather conditions. The results are used to calculate the corresponding sound power levels which are then compared to results calculated with the well-known BPA and EPRI equations for AC and DC audible noise prediction. The approach used to calculate the sound power levels of conductor bundles by measuring audible noise at fixed immission points is explained in great detail. The investigations show good agreement between laboratory results and AN predictions for AC OHL. However, some differences have been noted in the case of DC. In the last part of this contribution the compiled results are used to predict audible noise levels for a European AC line and for the planned HVDC-link between Sumatra and Java.
[1]
M. Temoshok,et al.
Relative Surface voltage Gradients of Grouped Conductors
,
1948,
Transactions of the American Institute of Electrical Engineers.
[2]
G. E. Adams.
Voltage Gradients on High-Voltage Transmission Lines [includes discussion]
,
1955,
Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.
[3]
Christian M. Franck,et al.
Audible noise of hybrid AC / DC overhead lines : Comparison of different prediction methods and conductor arrangements
,
2015
.
[4]
Essam Nasser,et al.
Digital Computer Calculation of the Potential and Its Gradient of a Twin Cylindrical Conductor
,
1969
.
[5]
H. Singer,et al.
A Charge Simulation Method for the Calculation of High Voltage Fields
,
1974
.
[6]
V. Chartier,et al.
Formulas for Predicting Audible Noise from Overhead High Voltage AC and DC Lines
,
1981,
IEEE Transactions on Power Apparatus and Systems.
[7]
L. E. Zaffanella,et al.
The Effect of HVAC-HVDC Line Separation in a Hybrid Corridor
,
1989,
IEEE Power Engineering Review.