A 850 GHz Waveguide Receiver Employing a Niobium SIS Junction Fabricated on a 1 μ m Si 3 N 4 Membrane

We report on a 850 GHz SIS heterodyne receiver employing a RF tuned niobium tunnel junction with a current density of 14kA/cm2, fabricated on a 1 μm Si3N4 supporting membrane. Since the mixer is designed to be operated well above the superconducting gap frequency of niobium (2 /h ≈ 690 GHz), special care has been taken to minimize niobium transmission line losses. Both Fourier Transform Spectrometer measurements of the direct detection performance and calculations of the IF output noise with the mixer operating in heterodyne mode, indicate an absorption loss in the niobium film of about 6.8 dB at 822 GHz. These results are in reasonably good agreement with the loss predicted by the Mattis-Bardeen theory in the extreme anomalous limit. From 800–840 GHz we report uncorrected receiver noise temperatures of 518K or 514K when we use Callen & Welton’s law to calculate the input load temperatures. Over the same frequency range, the mixer has a 4 dB conversion loss and 265K ± 10K noise temperature. At 890 GHz the sensitivity of the receiver has degraded to 900K, which is primarily the result of increased niobium film loss in the RF matching network. When the mixer was cooled from 4.2K to 1.9K the receiver noise temperature improved about 20% to 409K DSB. Approximately half of the receiver noise temperature improvement can be attributed to a lower mixer conversion loss, while the remainder is due to a reduction in the niobium film absorption loss. At 982 GHz we measured a receiver noise temperature

[1]  P. Feautrier,et al.  A low-noise SIS receiver measured from 480 GHz to 650 GHz using Nb junctions with integrated RF tuning circuits , 1994 .

[2]  Bruce Bumble,et al.  The development of an 850 GHz waveguide receiver using tuned sis junctions on 1µm Si3N4 membranes , 1995 .

[3]  G. G. Ortiz,et al.  A cooled 1-2 GHz balanced HEMT amplifier , 1991 .

[4]  M. J. Feldman,et al.  MMA Memo 161 Receiver Noise Temperature, the Quantum Noise Limit, and the Role of the Zero-Point Fluctuations * , 1996 .

[5]  T. Claeson,et al.  High-frequency limits of superconducting tunnel junction mixers , 1987 .

[6]  Jonas Zmuidzinas,et al.  Quasi-optical slot antenna SIS mixers , 1991 .

[7]  J. W. Kooi,et al.  230 and 492 GHz low noise sis waveguide receivers employing tuned Nb/AlOx/Nb tunnel junctions , 1994 .

[8]  H. Callen,et al.  Irreversibility and Generalized Noise , 1951 .

[9]  Anders Skalare,et al.  Determining embedding circuit parameters from DC measurements on quasiparticle mixers , 1989 .

[10]  T. Crowe,et al.  An All Solid-State 1 THz Radiometer For Space Applications , 1995 .

[11]  Henry G. Leduc,et al.  A low noise 230 GHz heterodyne receiver employing 0.25- mu m/sup 2/ area Nb-AlO/sub x/-Nb tunnel junctions , 1992 .

[12]  B. N. Ellison,et al.  A low noise 230 GHz sis receiver , 1987 .

[13]  S. Padin,et al.  On Using the Shot Noise in SIS Tunnel Junctions for Characterizing IF Amplifiers , 1995 .

[14]  Marc J. Feldman,et al.  Quantum detection at millimeter wavelengths , 1985 .

[15]  Raymond Blundell,et al.  Understanding noise in SIS receivers , 1992 .

[16]  J. Lange,et al.  Noise Characterization of Linear Twoports in Terms of Invariant Parameters , 1967 .

[17]  J. E. Carlstrom,et al.  A low-noise 492 GHz SIS waveguide receiver , 1992 .

[18]  D. Mattis,et al.  Theory of the anomalous skin effect in normal and superconducting metals , 1958 .

[19]  P.D. Maker,et al.  A fixed tuned broadband matching structure for submillimeter SIS receivers , 1992, IEEE Transactions on Applied Superconductivity.

[20]  Pascal Febvre,et al.  An SIS waveguide heterodyne receiver for 600 HGz-635 GHz , 1994 .

[21]  S. Rudner,et al.  Superconductor‐insulator‐superconductor mixing with arrays at millimeter‐wave frequencies , 1981 .

[22]  M. Wengler,et al.  Quantum noise in heterodyne detection , 1987 .

[23]  H. Huggins,et al.  High quality refractory Josephson tunnel junctions utilizing thin aluminum layers , 1983 .

[24]  M. J. Wengler,et al.  85--115-GHz Receivers for Radio Astronomy , 1985 .

[25]  J. Zmuidzinas,et al.  Shot noise and photon-induced correlations in 500 GHz SIS detectors , 1995, IEEE Transactions on Applied Superconductivity.

[26]  R. Poepel Electromagnetic Properties of Superconductors , 1989 .

[27]  M. J. Feldman,et al.  A technique for noise measurements of SIS receivers , 1994 .

[28]  J. W. Kooi,et al.  A lownoise 665 GHz SIS quasi-particle waveguide receiver , 1994 .