Spectroscopic blood component measurement by using reduced ranges of absorption spectra

Predicting concentrations of aqueous glucose solutions using reduced wavelength components is presented. The wavelengths are selected based on the second derivative of the near-infrared absorbance spectra. In the demonstration of the temperature-insensitive partial least squares analysis, good agreement between actual glucose concentrations and predicted values is verified.

[1]  J D Kruse-Jarres,et al.  Multivariate determination of glucose in whole blood by attenuated total reflection infrared spectroscopy. , 1989, Analytical chemistry.

[2]  M A Arnold,et al.  Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra. , 1990, Analytical chemistry.

[3]  Kevin H. Hazen,et al.  Temperature-Insensitive Near-Infrared Spectroscopic Measurement of Glucose in Aqueous Solutions , 1994 .

[4]  E. V. Thomas,et al.  Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation. , 1992, Clinical chemistry.

[5]  M Essenpreis,et al.  The influence of glucose concentration upon the transport of light in tissue-simulating phantoms. , 1995, Physics in medicine and biology.

[6]  Junzo Umemura,et al.  Separation of Raman spectra from fluorescence emission background by principal component analysis , 2000 .

[7]  Masatoshi Tarumi,et al.  Monte Carlo simulation of NIR spectrum changes induced by variations of glucose concentration , 2002, SPIE BiOS.

[8]  M A Arnold,et al.  Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by Fourier transform near-infrared spectroscopy. , 1993, Analytical chemistry.

[9]  Kevin H. Hazen,et al.  Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy , 1998 .

[10]  B. Wilson,et al.  Monte Carlo modeling studies of the effect of physiological factors andother analytes on the determination of glucose concentration in vivoby near infrared optical absorption and scattering measurements. , 1997, Journal of biomedical optics.

[11]  S. Thennadil,et al.  Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm. , 2001, Journal of biomedical optics.

[12]  Yukio Yamada,et al.  Temperature-Insensitive Measurement of Glucose Concentration Based on Near Infrared Spectroscopy and Partial Least Squares Analysis , 2003 .

[13]  J. S. Dam,et al.  Multiple polynomial regression method for determination of biomedical optical properties from integrating sphere measurements. , 2000, Applied optics.

[14]  M. Kohl,et al.  Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. , 1998, Physics in medicine and biology.

[15]  B Chance,et al.  Dependence of tissue optical properties on solute-induced changes in refractive index and osmolarity. , 1996, Journal of biomedical optics.