Simplified normal limits and automated quantitative assessment for attenuation-corrected myocardial perfusion SPECT

BackgroundWe aimed to compare normal limits and the detection of coronary artery disease (CAD) with attenuation-corrected (AC) and non-attenuation-corrected (NC) myocardial perfusion single photon emission computed tomography (MPS) by use of a recently improved automated quantification technique.Methods and ResultsWe acquired 415 rest/stress technetium 99m MPS studies on a Vertex dual-detector camera with a gadolinium 153 line source (Vantage Pro). Gender-specific NC, AC, and gender-combined AC normal limits were created from rest/stress images of 50 women and 50 men with a low likelihood of CAD (<5%) and a median body mass index (BMI) of 30 kg/m2 in each gender group. BMI-specific normal limits (<30 kg/m2 and >30 kg/m2) were also compared. Total perfusion deficit and 17-segment summed scores in 174 patients were compared with angiography, and normalcy rates were established from 141 studies of low-likelihood patients. There were no differences between low-BMI and high-BMI normal limits for AC or NC studies. Male and female normal limits differed in 12 of 17 segments for NC stress studies and in 3 of 17 segments for AC stress studies (P < .01). The sensitivity, specificity, and normalcy rates for stenoses with 70% narrowing or greater were 89%, 73%, and 91%, respectively, for NC studies and 87%, 80%, and 95%, respectively, for AC studies (P = not significant).ConclusionAutomated detection of CAD by AC and NC MPS demonstrated similar sensitivity, specificity, and normalcy rates. Some gender differences were noted for AC normal limits.

[1]  J. Case,et al.  Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[2]  Brad Kemp,et al.  A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[3]  G Germano,et al.  A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Oliver Lindner,et al.  Attenuation correction of myocardial SPECT perfusion images with low-dose CT: evaluation of the method by comparison with perfusion PET. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Guido Germano,et al.  Automatic quantification of myocardial perfusion stress-rest change: a new measure of ischemia. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  R. Hendel,et al.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[7]  J. Sýkora,et al.  Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities , 1998, European Journal of Nuclear Medicine.

[8]  Jonathan M Links,et al.  Clinical significance of apical thinning after attenuation correction , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[9]  Guido Germano,et al.  Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  R. Hendel,et al.  American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[11]  D. Berman,et al.  Extent and severity of myocardial hypoperfusion as predictors of prognosis in patients with suspected coronary artery disease. , 1986, Journal of the American College of Cardiology.

[12]  J. Hanley,et al.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases. , 1983, Radiology.

[13]  G V Heller,et al.  Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging. , 1999, Circulation.

[14]  T Sharir,et al.  Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease , 1998, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[15]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Circulation.

[16]  Guido Germano,et al.  Automatic detection and size quantification of infarcts by myocardial perfusion SPECT: clinical validation by delayed-enhancement MRI. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  J M Links,et al.  Combined corrections for attenuation, depthdependent blur, and motion in cardiac SPECT: A multicenter trial , 2000, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[18]  D. Berman,et al.  Automated quantification of myocardial perfusion SPECT using simplified normal limits , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[19]  M Schwaiger,et al.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  R. Kluge,et al.  Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer: impact on diagnostic accuracy , 1997, European Journal of Nuclear Medicine.

[21]  D. Berman,et al.  Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  Jonathan M. Links,et al.  Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[23]  Frans J. Th. Wackers,et al.  Clinical validation of SPECT attenuation correction using x-ray computed tomography—derived attenuation maps: Multicenter clinical trial with angiographic correlation , 2005, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[24]  D. Berman,et al.  Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  R. Castillo,et al.  Attenuation correction of PET images with respiration-averaged CT images in PET/CT. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  P. Jarritt,et al.  Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease , 1997, European Journal of Nuclear Medicine.

[27]  Oliver Lindner,et al.  A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT Introduced by misalignment between emission scan and CT-derived attenuation maps. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[28]  J. Fessler,et al.  Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography. , 1996, Circulation.

[29]  Sibylle Ziegler,et al.  PET/CT: challenge for nuclear cardiology. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[30]  G. Diamond,et al.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. , 1979, The New England journal of medicine.

[31]  Russell D Folks,et al.  Quantitative Tc-99m sestamibi attenuation-corrected SPECT: Development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[32]  B. D. Bauman,et al.  Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[33]  Randall C. Thompson,et al.  Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index , 2005, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[34]  M Schwaiger,et al.  Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.