A Method for Reducing Secondary Field Effects in Asymmetric MRI Gradient Coil Design

Goal: This research introduces an original method for the design of MRI gradient coils that reduces secondary field effects created by eddy current coupling. The method is able to deal with asymmetric coils and provides a new way to ensure a reduction in the magnitude of the eddy current induced fields. Methods: New constraints are introduced at the surface of passive objects to bind the normal field component below a given value. This value is determined by first treating the passive surface as an active surface, and then, calculating the ideal stream function on that surface to produce the desired secondary field. Two coils were designed, one to image the knee and the other to image the head and neck. Results: The secondary field was analyzed using linear regression and was found to improve the secondary field from 10.41 to 0.498 mT/m and from 7.84 to 0.286 mT/m in the examples used. The power loss in the passive structure also decreased to below 1% of the original value using the new method. Conclusion: The method shows the ability to constrain the field to values below the minimum seen under the traditional approaches. Significance: This will allow the design of asymmetric systems with highly linear, reduced magnitude of secondary fields and may lead to better image quality.

[1]  A. Kameari Transient eddy current analysis on thin conductors with arbitrary connections and shapes , 1981 .

[2]  P. Mansfield,et al.  Active magnetic screening of coils for static and time-dependent magnetic field generation in NMR imaging , 1986 .

[3]  R. Turner,et al.  Passive screening of switched magnetic field gradients , 1986 .

[4]  R. Turner Minimum inductance coils , 1988 .

[5]  G. Ries Eddy current transients and forces in cryostat walls of superconducting solenoids , 1988 .

[6]  P. Jehenson,et al.  Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems , 1990 .

[7]  C. Boesch,et al.  Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimization of corrections and quantitative characterization of magnet/gradient systems , 1991, Magnetic resonance in medicine.

[8]  H. Pfeifer Principles of Nuclear Magnetic Resonance Microscopy , 1992 .

[9]  J. Carlson,et al.  Design and evaluation of shielded gradient coils , 1992, Magnetic resonance in medicine.

[10]  S. Pissanetzky Minimum energy MRI gradient coils of general geometry , 1992 .

[11]  R. Turner,et al.  Gradient coil design: a review of methods. , 1993, Magnetic resonance imaging.

[12]  R. Bowtell,et al.  Active Acoustic Screening: Reduction of Noise in Gradient Coils by Lorentz Force Balancing , 1995, Magnetic resonance in medicine.

[13]  D. Alsop,et al.  Optimization of torque‐balanced asymmetric head gradient coils , 1996, Magnetic resonance in medicine.

[14]  A. Caprihan,et al.  A programmable pre‐emphasis system , 1998, Magnetic resonance in medicine.

[15]  B. Rutt,et al.  Design and fabrication of a three‐axis edge ROU head and neck gradient coil , 2000, Magnetic resonance in medicine.

[16]  G. Peeren Stream function approach for determining optimal surface currents , 2003 .

[17]  Feng Liu,et al.  Analysis of Transient Eddy Currents in MRI Using a Cylindrical FDTD Method , 2006, IEEE Transactions on Applied Superconductivity.

[18]  S. Crozier,et al.  A Simple Relationship for High Efficiency–Gradient Uniformity Tradeoff in Multilayer Asymmetric Gradient Coils for Magnetic Resonance Imaging , 2007, IEEE Transactions on Magnetics.

[19]  Richard Bowtell,et al.  Novel gradient coils designed using a boundary element method , 2007 .

[20]  D. Porter,et al.  Concomitant field terms for asymmetric gradient coils: Consequences for diffusion, flow, and echo‐planar imaging , 2008, Magnetic resonance in medicine.

[21]  K. Thulborn,et al.  Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo‐time and time‐varying gradients , 2009, Magnetic resonance in medicine.

[22]  Feng Liu,et al.  Equivalent Magnetization Current Method Applied to the Design of Gradient Coils for Magnetic Resonance Imaging , 2009, IEEE Transactions on Magnetics.

[23]  M. Abe A Design Technique of MRI Active Shield Gradient Coil Using Node Current Potentials and Triangular Finite Elements , 2014, IEEE Transactions on Magnetics.

[24]  M. Repetto,et al.  Skin and proximity effects in the conductors of split gradient coils for a hybrid Linac-MRI scanner. , 2014, Journal of magnetic resonance.

[25]  M. Repetto,et al.  Multilayer integral method for simulation of eddy currents in thin volumes of arbitrary geometry produced by MRI gradient coils , 2014, Magnetic resonance in medicine.

[26]  Christan G. Cabou Analytical Method for the Compensation of Eddy – Current Effects Induced by Pulsed Magnetic Field Gradients in NMR Systems , 2017 .