Flat-field calibration method for hyperspectral frame cameras

This paper presents a method for characterising spatial responsivity of hyperspectral cameras. Knowing the responsivity of the camera as a function of pixel coordinates allows applying a flat-field correction on image data. The method is based on scanning the field of view of the camera with a broadband radiance source, based on an integrating sphere, and combining the captured frames to synthesise a uniform radiance source filling the whole field of view of the camera at the focus distance. The method was compared with a traditional approach where the aperture of an integrating sphere is imaged from a close distance, filling the entire field of view of the camera. The measurement setup was tested with a hyperspectral camera, based on a tunable Fabry–Pérot interferometer. Without the flat-field correction, the average standard deviation of the pixel responsivities across all the spectral channels of the camera was 3.78%. After the correction, the average standard deviation was reduced to 0.40% and 3.25% for the aperture-scanning method and the close-distance method, respectively. The expanded uncertainty (k = 2) for the flat-field correction obtained using the scanning method was 0.68%–0.78%, depending on the spectral channel of the camera.

[1]  Heikki Saari,et al.  Miniaturized hyperspectral imager calibration and UAV flight campaigns , 2013, Remote Sensing.

[2]  Jung Soh,et al.  Vignetting distortion correction method for high quality digital imaging , 2004, Proceedings of the 17th International Conference on Pattern Recognition, 2004. ICPR 2004..

[3]  Arko Lucieer,et al.  HyperUAS—Imaging Spectroscopy from a Multirotor Unmanned Aircraft System , 2014, J. Field Robotics.

[4]  Arko Lucieer,et al.  Sensor Correction of a 6-Band Multispectral Imaging Sensor for UAV Remote Sensing , 2012, Remote. Sens..

[5]  Hans-Peter Röser,et al.  Hyperspectral Remote Sensing with the UAS “Stuttgarter Adler” – System Setup, Calibration and First Results , 2014 .

[6]  Marc Pollefeys,et al.  Robust Radiometric Calibration and Vignetting Correction , 2008, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[7]  C. Shaddix,et al.  Simultaneous correction of flat field and nonlinearity response of intensified charge-coupled devices. , 2007, The Review of scientific instruments.

[8]  Andreas Burkart,et al.  Generating 3D hyperspectral information with lightweight UAV snapshot cameras for vegetation monitoring: From camera calibration to quality assurance , 2015 .

[9]  Heikki Saari,et al.  Processing and Assessment of Spectrometric, Stereoscopic Imagery Collected Using a Lightweight UAV Spectral Camera for Precision Agriculture , 2013, Remote. Sens..

[10]  E. Ikonen,et al.  Fisheye camera method for spatial non-uniformity corrections in luminous flux measurements with integrating spheres , 2017 .

[11]  Eija Honkavaara,et al.  Quantitative Remote Sensing at Ultra-High Resolution with UAV Spectroscopy: A Review of Sensor Technology, Measurement Procedures, and Data Correction Workflows , 2018, Remote. Sens..

[12]  Michael Stock,et al.  Practical aspects of aperture-area measurements by superposition of Gaussian laser beams , 2000 .

[13]  Juha Suomalainen,et al.  A Lightweight Hyperspectral Mapping System and Photogrammetric Processing Chain for Unmanned Aerial Vehicles , 2014, Remote. Sens..

[14]  Heikki Saari,et al.  Novel miniaturized hyperspectral sensor for UAV and space applications , 2009, Remote Sensing.

[15]  Peter Gege,et al.  Calibration facility for airborne imaging spectrometers , 2005 .

[16]  Erkki Ikonen,et al.  A new optical method for high-accuracy determination of aperture area , 1998 .

[17]  Eija Honkavaara,et al.  Direct Reflectance Measurements from Drones: Sensor Absolute Radiometric Calibration and System Tests for Forest Reflectance Characterization , 2018, Sensors.

[18]  Huanhuan Yuan,et al.  The DOM Generation and Precise Radiometric Calibration of a UAV-Mounted Miniature Snapshot Hyperspectral Imager , 2017, Remote. Sens..

[19]  W. Wild RECONSTRUCTING FLAT FIELDS FROM NON-UNIFORM BACKGROUND ILLUMINATION SOURCES , 1997 .

[20]  Joaquin Campos,et al.  Radiometric calibration of charge-coupled-device video cameras , 2000 .

[21]  Ping Li,et al.  Computer modeling of a large-area integrating sphere uniform radiation source for calibration of satellite remote sensors , 2011 .

[22]  Heikki Saari,et al.  Unmanned aerial vehicle (UAV) operated megapixel spectral camera , 2011, Security + Defence.

[23]  A. Ferrero,et al.  Correction of photoresponse nonuniformity for matrix detectors based on prior compensation for their nonlinear behavior. , 2006, Applied optics.

[24]  John M. Boone,et al.  Flat-field correction technique for digital detectors , 1998, Medical Imaging.

[25]  Jeffrey H. Bowles,et al.  Calibration of inexpensive pushbroom imaging spectrometers , 1998 .

[26]  Alejandro Ferrero,et al.  Low-uncertainty absolute radiometric calibration of a CCD , 2006 .

[27]  Wonpil Yu,et al.  Practical anti-vignetting methods for digital cameras , 2004, IEEE Trans. Consumer Electron..

[28]  Juha Hyyppä,et al.  Individual Tree Detection and Classification with UAV-Based Photogrammetric Point Clouds and Hyperspectral Imaging , 2017, Remote. Sens..

[29]  Yoav Y Schechner,et al.  Radiometric framework for image mosaicking. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[30]  Heikki Saari,et al.  Remote Sensing of 3-D Geometry and Surface Moisture of a Peat Production Area Using Hyperspectral Frame Cameras in Visible to Short-Wave Infrared Spectral Ranges Onboard a Small Unmanned Airborne Vehicle (UAV) , 2016, IEEE Transactions on Geoscience and Remote Sensing.

[31]  Dan B. Goldman,et al.  Vignette and exposure calibration and compensation , 2005, Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1.

[32]  J. Dymond,et al.  Directional reflectance of vegetation measured by a calibrated digital camera. , 1997, Applied optics.

[33]  Erkki Ikonen,et al.  An optical method for direct determination of the radiometric aperture area at high accuracy , 1997 .

[34]  E. Honkavaara,et al.  Geometric Calibration of a Hyperspectral Frame Camera , 2016 .