The ESTRO-QUALity assurance network (EQUAL).

BACKGROUND AND PURPOSE ESTRO has set up a Quality Assurance network (EQUAL) to check the dose delivered on axis in reference and non-reference conditions for external radiotherapy. The external audits covered by the network are based on measurements made with mailed thermoluminescent dosimeters (TLD). MATERIAL AND METHODS The TLD consist of LiF powder type DTL 937 read with a PCL 3 automatic TLD reader. The participating centres are instructed to deliver to the TLDs absorbed doses of 2 Gy calculated with the Treatment Planning System used in clinical routine. A maximum of three photon energies by participating centre have been checked with 10 on-axis points per beam. The quantities checked include the reference beam output, beam output variation with collimator opening, depth dose data and wedge transmission factor. RESULTS During the 1998 EQUAL programme 102 centres have been checked corresponding to 235 beams (28 (60)Co beams and 207 X-ray beams). About 3% of the outputs in reference conditions show deviations outside tolerance level (>+/-5%). A similar rate of deviation is noted for the percentage depth doses. A rate of deviation (6%) has been observed for the beam output variation (open and wedged beams) and the wedge transmission factor. The analysis of the results shows that for 24 out of the 102 centres, a deviation outside tolerance level is observed at least in one point, mainly for the large and rectangular field sizes and for the wedged beams. CONCLUSIONS The results for the EQUAL programme show the importance of a quality assurance network in Radiotherapy especially for the non reference points even if they are only located on the beam axis (In order to participate in this network, please contact EQUAL secretariat or download the attached application form ESTRO web site: Dr I.H. Ferreira or Mrs Aline Mechet, EQUAL-ESTRO, Physics Department, Institut Gustave-Roussy 39 Rue Camille Desmoulins, F-94805 Villejuif Cedex, France. e-mail:equal@igr.fr or http://www.estro.be/).

[1]  J. Izewska,et al.  Quality Assurance Network in Central Europe: External audit on output calibration for photon beams , 1995 .

[2]  H. Svensson,et al.  The IAEA/WHO TL dosimetry service for radiotherapy centres 1969-87. , 1990, Acta oncologica.

[3]  A. Boyer,et al.  Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters. , 1980, Medical physics.

[4]  Cristina Garibaldi,et al.  MONITOR UNIT CALCULATION FOR HIGH ENERGY PHOTON BEAMS - PRACTICAL EXAMPLES , 1997 .

[5]  A. Dutreix,et al.  A European quality assurance network for radiotherapy: dose measurement procedure. , 1995, Physics in Medicine and Biology.

[6]  A Dutreix,et al.  Quality control of radiotherapy centres in Europe: beam calibration. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  A Nisbet,et al.  A dosimetric intercomparison of electron beams in UK radiotherapy centres. , 1997, Physics in medicine and biology.

[8]  K. Johansson,et al.  Quality audit of radiotherapy with EORTC mailed in water TL-dosimetry. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  D. Thwaites,et al.  A dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  G. Portal,et al.  New Automatic Fast Reader for Powder or Sintered Pellets used in Medical Physics , 1990 .

[11]  E. Van Der Schueren,et al.  A quality assurance network in Central European countries--radiotherapy infrastructure. , 1998, Acta oncologica.

[12]  A. Dutreix,et al.  Preliminary results of a quality assurance network for radiotherapy centres in Europe , 1994 .

[13]  E. Van Der Schueren,et al.  The influence of the IAEA standard holder on dose evaluated from TLD samples. , 1996, Physics in medicine and biology.

[14]  P Andreo,et al.  The IAEA/WHO TLD postal programme for radiotherapy hospitals. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  D I Thwaites,et al.  A dosimetric intercomparison of megavoltage photon beams in UK radiotherapy centres. , 1992, Physics in medicine and biology.