A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation

Background: Recent studies have shown that subclinical valve thrombosis in heart valve prosthesis (HVP) can be responsible for reduced leaflet motion detectable only by advanced imaging diagnostics. We conceived a novel sensorized HVP able to detect earlier any thrombus formation that may alter the leaflets motion using an electric impedance measurement, IntraValvular Impedance (IVI). Methods: For IVI measurement, dedicated electrodes are embedded in the structure of the HVP to generate a local electric field that is altered by the moving valve leaflets during their cyclic opening/closing. We present preliminary in vitro results using a first prototype of sensorized mechanical heart valve connected to an external impedance measurement system. The prototype was tested on a circulatory mock loop system and the IVI signals were recorded during both normal dynamics and experimentally induced altered working of the leaflets. Results: Recordings showed a very repetitive and stable IVI signal during the normal cyclic opening/closing of the HVP. The induced alterations in leaflet motion were reflected in the IVI signal. Conclusions: The novel sensorized HVP has great potential to give early warning of possible subclinical valve thrombosis altering the valve leaflet motion, and to help in tailoring the anticoagulation therapy.

[1]  Laura Cercenelli,et al.  How to transform a fixed stroke alternating syringe ventricle into an adjustable elastance ventricle. , 2018, The Review of scientific instruments.

[2]  Deepak L. Bhatt,et al.  Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves. , 2015, The New England journal of medicine.

[3]  B. Iung,et al.  The modern epidemiology of heart valve disease , 2015, Heart.

[4]  P. Pibarot,et al.  Prosthetic Heart Valves Selection of the Optimal Prosthesis and Long-Term Management , 2009 .

[5]  Lissa Sugeng,et al.  Bioprosthetic Valve Thrombosis , 2006, Echocardiography.

[6]  J. Leipsic,et al.  Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves. , 2016, European heart journal.

[7]  Jennifer Taylor,et al.  ESC/EACTS Guidelines on the management of valvular heart disease. , 2012, European heart journal.

[8]  W. Mali,et al.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction , 2011, Nature Reviews Cardiology.

[9]  S Achenbach,et al.  Leaflet thrombosis following transcatheter aortic valve implantation. , 2017, Journal of cardiovascular computed tomography.

[10]  Roxana Mehran,et al.  Prosthetic Heart Valve Thrombosis. , 2016, Journal of the American College of Cardiology.

[11]  C. Terkelsen,et al.  Transcatheter Aortic Valve Thrombosis: Incidence, Predisposing Factors, and Clinical Implications. , 2016, Journal of the American College of Cardiology.

[12]  Wen Cheng,et al.  Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study , 2017, The Lancet.

[13]  Helmut Baumgartner,et al.  [2017 ESC/EACTS Guidelines for the management of valvular heart disease]. , 2017, Kardiologia polska.

[14]  J. Bonnet,et al.  Measurement of Minute Ventilation with Different DDDR Pacemaker Electrode Configurations , 1998, Pacing and clinical electrophysiology : PACE.

[15]  M. Multigner,et al.  Magnetic Sensor for Early Detection of Heart Valve Bioprostheses Failure , 2007 .

[16]  R. Shandas,et al.  Development and validation of implantable sensors for monitoring function of prosthetic heart valves:in vitro studies , 2003, Medical and Biological Engineering and Computing.

[17]  Andre Lamy,et al.  Antithrombotic management of patients with prosthetic heart valves: current evidence and future trends , 2009, The Lancet.

[18]  K. Serri,et al.  Thrombosis of prosthetic heart valves: diagnosis and therapeutic considerations , 2006, Heart.

[19]  M. Mack,et al.  Aortic Valve Bioprostheses: Leaflet Immobility and Valve Thrombosis , 2017, Circulation.

[20]  Laura Cercenelli,et al.  Cardiorespiratory Mechanical Simulator for In Vitro Testing of Impedance Minute Ventilation Sensors in Cardiac Pacemakers , 2016, ASAIO journal.

[21]  Patricia A Pellikka,et al.  Misconceptions, diagnostic challenges and treatment opportunities in bioprosthetic valve thrombosis: lessons from a case series. , 2015, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[22]  D Hunt,et al.  Rate Responsive Pacing Using a Minute Ventilation Sensor , 1988, Pacing and clinical electrophysiology : PACE.

[23]  H. Rashid,et al.  Subclinical Leaflet Thrombosis in Transcatheter Aortic Valve Replacement Detected by Multidetector Computed Tomography - A Review of Current Evidence. , 2018, Circulation journal : official journal of the Japanese Circulation Society.

[24]  Philippe Pibarot,et al.  Subclinical bioprosthetic aortic valve thrombosis: clinical and translational implications , 2016, Current opinion in cardiology.

[25]  Alec Vahanian,et al.  Epidemiology of valvular heart disease in the adult , 2011, Nature Reviews Cardiology.

[26]  Patricia A Pellikka,et al.  Bioprosthetic Valve Thrombosis Versus Structural Failure: Clinical and Echocardiographic Predictors. , 2015, Journal of the American College of Cardiology.