A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning

An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equallyspaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality.

[1]  Radhe Mohan,et al.  Iterative solution methods for beam angle and fluence map optimization in intensity modulated radiation therapy planning , 2008, OR Spectr..

[2]  Peter A S Johnstone,et al.  Dosimetric comparison of manual and beam angle optimization of gantry angles in IMRT. , 2011, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[3]  Gino J. Lim,et al.  A two-phase method for selecting IMRT treatment beam angles: Branch-and-Prune and local neighborhood search , 2012, Eur. J. Oper. Res..

[4]  Margie Hunt,et al.  Choosing an intensity-modulated radiation therapy technique in the treatment of head-and-neck cancer. , 2007, International journal of radiation oncology, biology, physics.

[5]  M. Monz,et al.  Simultaneous navigation of multiple Pareto surfaces, with an application to multicriteria IMRT planning with multiple beam angle configurations. , 2010, Medical physics.

[6]  Eva K. Lee,et al.  Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[7]  Sumit Basu,et al.  An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors , 2012, Journal of applied clinical medical physics.

[8]  Leyuan Shi,et al.  Nested Partitions Method for Global Optimization , 2000, Oper. Res..

[9]  Sha X. Chang,et al.  Beam orientation selection for intensity-modulated radiation therapy based on target equivalent uniform dose maximization. , 2001, International journal of radiation oncology, biology, physics.

[10]  Sumit Basu,et al.  An algorithm for fast beam angle selection in intensity modulated radiotherapy. , 2010, Medical physics.

[11]  Radhe Mohan,et al.  Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinoma. , 2005, International journal of radiation oncology, biology, physics.

[12]  Valentina Cacchiani,et al.  A hybrid approach to beam angle optimization in intensity-modulated radiation therapy , 2013, Comput. Oper. Res..

[13]  D. Craft Local beam angle optimization with linear programming and gradient search , 2007, Physics in medicine and biology.

[14]  Peter C Levendag,et al.  Computer optimization of noncoplanar beam setups improves stereotactic treatment of liver tumors. , 2006, International journal of radiation oncology, biology, physics.

[15]  Leyuan Shi,et al.  Solving Beam-Angle Selection and Dose Optimization Simultaneously via High-Throughput Computing , 2009, INFORMS J. Comput..

[16]  Uwe Oelfke,et al.  Spherical cluster analysis for beam angle optimization in intensity-modulated radiation therapy treatment planning , 2010, Physics in medicine and biology.

[17]  Leyuan Shi,et al.  A nested partitions framework for beam angle optimization in intensity-modulated radiation therapy , 2008, Physics in medicine and biology.

[18]  Ben J M Heijmen,et al.  iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans. , 2012, Medical physics.

[19]  Steve B. Jiang,et al.  Beam orientation optimization for intensity modulated radiation therapy using adaptive l2,1-minimization , 2011, Physics in medicine and biology.

[20]  J. Waldron,et al.  Radiation therapy for head and neck cancers. , 2009, Seminars in oncology nursing.

[21]  Boyd McCurdy,et al.  PARETO: A novel evolutionary optimization approach to multiobjective IMRT planning. , 2011, Medical physics.

[22]  Matthew D. Jones,et al.  Optimization of beam angles for intensity modulated radiation therapy treatment planning using genetic algorithm on a distributed computing platform , 2009, Journal of medical physics.

[23]  M. Sharpe,et al.  A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation , 2011, Physics in medicine and biology.

[24]  Lei Dong,et al.  Development of methods for beam angle optimization for IMRT using an accelerated exhaustive search strategy. , 2004, International journal of radiation oncology, biology, physics.

[25]  Boyd McCurdy,et al.  A simple geometric algorithm to predict optimal starting gantry angles using equiangular-spaced beams for intensity modulated radiation therapy of prostate cancer. , 2007, Medical physics.

[26]  Radhe Mohan,et al.  Beam angle optimization and reduction for intensity-modulated radiation therapy of non-small-cell lung cancers. , 2006, International journal of radiation oncology, biology, physics.

[27]  Eugene Wong,et al.  Intensity modulated radiotherapy of non-small-cell lung cancer incorporating SPECT ventilation imaging. , 2010, Medical physics.

[28]  T. Bortfeld,et al.  Optimization of beam orientations in radiation therapy: some theoretical considerations. , 1993, Physics in medicine and biology.