Evaluation of the effect of urine dip vs urine drip on multi-test strip results.

Standard operating procedures, including World Health Organization guidelines for packed cell volume, are established for in-clinic laboratory tests. No independent, evidence-based guidelines exist for dipstick urinalysis; however, manufacturer's instructions state to dip the stick into urine. In veterinary medicine, small volume urine samples could preclude dipping; therefore, a single drip per pad from a pipette or syringe is often performed. This study aimed to examine the differences between these two urine application methods prior to analysis, with the hypothesis that the method type would not effect on test results of dipstick analysis. To standardize the strip analysis method, a Siemens Clinitek Status + analyzer was used with Multistix10SG dipsticks. Three investigators tested urines from 53 dogs with a range of diseases by both methods. Results were assessed for the degree of agreement between the methods and within method variability. Overall, the agreement between methods was high. Within each method, the drip method variability was higher than that of the dip method (P = 0.012). Disagreements between methods were present, with pH and blood having the lowest agreement levels. Glucose was more likely to be positive on the drip compared with the dip methodology. This study demonstrates potential clinically relevant differences between the two methods and a higher level of variability with the drip methodology. Therefore, while the drip method could be used for practical reasons (eg, low sample volumes), this study supports the manufacturer's recommended method of dipping the dip stick into urine rather than dripping urine onto each pad with a pipette or syringe.

[1]  I. Handel,et al.  Urine dipstick precision with standard visual and automated methods within a small animal teaching hospital , 2018, Veterinary Record.

[2]  Jessica N. Busler,et al.  Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats. , 2018, American journal of veterinary research.

[3]  L. Guardabassi,et al.  Effects of Diagnostic Work‐Up on Medical Decision‐Making for Canine Urinary Tract Infection: An Observational Study in Danish Small Animal Practices , 2018, Journal of veterinary internal medicine.

[4]  S. Hazel,et al.  Influence of the Environment on Body Temperature of Racing Greyhounds , 2016, Front. Vet. Sci..

[5]  H. Beaufrère,et al.  Assessment of a veterinary dipstick for determination of urine protein/creatinine ratio in canines. , 2014, Journal of the American Animal Hospital Association.

[6]  J. Bonagura,et al.  Comparison of Forelimb and Hindlimb Systolic Blood Pressures and Proteinuria in Healthy Shetland Sheepdogs , 2014, Journal of veterinary internal medicine.

[7]  L. Aresu,et al.  Evaluation of kidney injury in dogs with pyometra based on proteinuria, renal histomorphology, and urinary biomarkers. , 2011, Journal of veterinary internal medicine.

[8]  G. Grauer Proteinuria: measurement and interpretation. , 2011, Topics in companion animal medicine.

[9]  M. Lappin,et al.  Comparison of urine dipstick, sulfosalicylic acid, urine protein-to-creatinine ratio, and species-specific ELISA methods for detection of albumin in urine samples of cats and dogs. , 2010, Journal of the American Veterinary Medical Association.

[10]  N. B. Olivier,et al.  Effect of semen in urine specimens on urine protein concentration determined by means of dipstick analysis. , 2010, American Journal of Veterinary Research.

[11]  A. Moritz,et al.  Evaluation the Clinitek status automated dipstick analysis device for semiquantitative testing of canine urine. , 2008, Research in veterinary science.

[12]  J. Lulich,et al.  Evaluation of the reproducibility and accuracy of pH-determining devices used to measure urine pH in dogs. , 2007, Journal of the American Veterinary Medical Association.