Thermal comfort and IAQ analysis of two Portuguese hospital buildings

In the last decades, public and governmental awareness on thermal comfort and indoor air quality (IAQ) has been growing. In buildings the number of potential pollutants is significant, and even low concentration levels can cause health problems (increased incidence of asthma and allergies, for example) if combined effects are considered. Therefore, the assessment of IAQ is very important to ensure health, well-being and productivity. This paper presents the results of a thermal comfort conditions and IAQ assessment of two hospital buildings with natural ventilation. The air temperature, the black bulb temperature, air velocity, relative humidity and the concentration of suspended particles, carbon dioxide, carbon monoxide, ozone, formaldehyde and total volatile organic compounds were measured. A standard questionnaire was delivered to the occupants to also obtain a subjective assessment of the thermal comfort and IAQ conditions. The goal of this study was to verify the thermal and IAQ conditions inside Portuguese hospital buildings. The results showed that, in general, the occupants were uncomfortable and that the main IAQ problems were related to high concentrations of carbon dioxide, volatile organic compounds and formaldehyde.

[1]  Jeong Tai Kim,et al.  Building Pathology, Investigation of Sick Buildings — VOC Emissions , 2010 .

[2]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[3]  G. Pershagen,et al.  Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to "dampness" in buildings and health effects (NORDDAMP). , 2001, Indoor air.

[4]  P. Fanger,et al.  Impact of Temperature and Humidity on the Perception of Indoor Air Quality , 1998 .

[5]  George Baird,et al.  The Potential for the Use of the Occupants’ Comments in the Analysis and Prediction of Building Performance , 2012 .

[6]  D Faulkner,et al.  Enhanced particle filtration in a non-problem office environment: preliminary results from a double-blind crossover intervention study. , 1999, American journal of industrial medicine.

[7]  Bjarne W. Olesen,et al.  Simulation of energy use, human thermal comfort and office work performance in buildings with modera , 2011 .

[8]  Constantinos A. Balaras,et al.  Deterioration of European apartment buildings , 2005 .

[9]  D Norbäck,et al.  Sick building syndrome and perceived indoor environment in relation to energy saving by reduced ventilation flow during heating season: a 1 year intervention study in dwellings. , 2005, Indoor air.

[10]  Ricardo Mateus,et al.  Sustainability assessment and rating of buildings: Developing the methodology SBTool PTH , 2011 .

[11]  Derek Clements-Croome Creating the Productive Workplace , 1999 .

[12]  Jagjit Singh,et al.  Building Pathology, Investigation of Sick Buildings —Toxic Moulds , 2010 .