Modelling of the Pressure Drop in Tangential Inlet Cyclone Separators

This article introduces a new mathematical model that predicts the pressure drop in a tangential inlet cyclone. The model calculates the pressure drop from the frictional losses in the cyclone body, using a wall friction coefficient based on the surface roughness and Reynolds number. The entrance and exit losses are also included in the model by defining new geometrical parameters. The pressure drop coefficient is obtained as a function of cyclone dimensions and operating conditions. The model is validated by studying 12 different cyclones presented in the literature. Comparison of the model results with predictions and measurements published in the literature show that the new model predicts the experimental results quite well for a wide range of operating conditions covering a flow rate of 0.3–220 l/s and a temperature range of 293–1200°K, in different cyclones. The pressure drop coefficient is also examined in view of the outlet pipe diameter, friction coefficient, surface roughness, and Reynolds number.

[1]  D. L. Iozia,et al.  Effect of Cyclone Dimensions on Gas Flow Pattern and Collection Efficiency , 1989 .

[2]  K. W. Lee,et al.  Effects of cone dimension on cyclone performance , 2001 .

[3]  K. W. Lee,et al.  EXPERIMENTAL STUDY ON SMALL CYCLONES OPERATING AT HIGH FLOWRATES , 1999 .

[4]  Madhumita B. Ray,et al.  Development of a post cyclone to improve the efficiency of reverse flow cyclones , 2000 .

[5]  K. W. Lee,et al.  Comparative performances of conventional cyclones and a double cyclone with and without an electric field , 2004 .

[6]  L. Ma,et al.  Predicting the performance of air cyclones , 2002 .

[7]  David Leith,et al.  The Logistic Function and Cyclone Fractional Efficiency , 1990 .

[8]  J. Derksen,et al.  An experimental and numerical study of turbulent swirling flow in gas cyclones , 1999 .

[9]  D. J. Hall,et al.  A wind tunnel evaluation of the physical sampling efficiencies of three bioaerosol samplers , 1994 .

[10]  R. I. Crane,et al.  Particulate behaviour in cyclone separators with secondary gas extraction , 1992 .

[11]  K. W. Lee,et al.  Experimental Study of Particle Collection by Small Cyclones , 1990 .

[12]  Noël Midoux,et al.  Comparison of different models of cyclone prediction performance for various operating conditions using a general software , 2004 .

[13]  B E Saltzman,et al.  Design and performance of miniature cyclones for respirable aerosol sampling. , 1983, Environmental science & technology.

[14]  Kenji Yoshida,et al.  Particle separation by Iinoya's type gas cyclone , 2001 .

[15]  Richard J. Munz,et al.  Cyclone collection efficiencies at very high temperatures , 1989 .

[16]  K. W. Lee,et al.  Exploratory design modifications for enhancing cyclone performance , 2001 .

[17]  W. D. Griffiths,et al.  Computational fluid dynamics (CFD) and empirical modelling of the performance of a number of cyclone samplers , 1996 .

[18]  C. E. Lapple,et al.  Flow Pattern and Pressure Drop in Cyclone Dust Collectors , 1939 .

[19]  A. Gil,et al.  Effect of the Solid Loading on a PFBC Cyclone with Pneumatic Extraction of Solids , 2002 .

[20]  I. Karagoz,et al.  Theoretical investigation of pressure losses in cyclone separators , 2001 .

[21]  Irfan Karagoz,et al.  Effects of flow and geometrical parameters on the collection efficiency in cyclone separators , 2003 .

[22]  Fábio Luı́s Fassani,et al.  A study of the effect of high inlet solids loading on a cyclone separator pressure drop and collection efficiency , 2000 .

[23]  M. Bohnet Influence of the gas temperature on the separation efficiency of aerocyclones , 1995 .

[24]  Alex C. Hoffmann,et al.  Advantages and risks in increasing cyclone separator length , 2001 .