On the Design of High-Rise Buildings for Multihazard: Fundamental Differences between Wind and Earthquake Demand
暂无分享,去创建一个
[1] Aly Mousaad Aly,et al. Proposed robust tuned mass damper for response mitigation in buildings exposed to multidirectional wind , 2014 .
[2] R. Scanlan,et al. Resonance, Tacoma Narrows bridge failure, and undergraduate physics textbooks , 1991 .
[3] Ahsan Kareem,et al. Dynamic Response of High-Rise Buildings to Stochastic Wind Loads , 1992 .
[4] James T. P. Yao,et al. CONCEPT OF STRUCTURAL CONTROL , 1972 .
[6] Alberto Zasso,et al. On the dynamics of a very slender building under winds: response reduction using MR dampers with lever mechanism , 2011 .
[7] N. Null. Minimum Design Loads for Buildings and Other Structures , 2003 .
[8] Xxyyzz,et al. Minimum Design Loads for Buildings and Other Structures , 1990 .
[9] Y. Kagan,et al. Earthquakes Cannot Be Predicted , 1997, Science.
[10] Stormy Attaway,et al. Matlab: A Practical Introduction to Programming and Problem Solving , 2009 .
[11] Emil Simiu,et al. Wind effects on structures : fundamentals and applications to design , 1996 .
[12] Bijan Samali,et al. Wind tunnel investigation of active vibration control of tall buildings , 1995 .
[13] Hiroo Kanamori,et al. Real-time seismology and earthquake hazard mitigation , 1997, Nature.
[14] Yue Li,et al. Framework for Multihazard Risk Assessment and Mitigation for Wood-Frame Residential Construction , 2009 .
[15] E. Simiu,et al. Multihazard Design: Structural Optimization Approach , 2009 .
[16] Ming Gu,et al. Experimental study of across‐wind aerodynamic damping of super high‐rise buildings with aerodynamically modified square cross‐sections , 2014 .
[18] C. Nomicos,et al. Discrimination between pre-seismic electromagnetic anomalies and solar activity effects , 2009 .
[19] Aly Mousaad Aly,et al. On the evaluation of the efficacy of a smart damper: a new equivalent energy-based probabilistic approach , 2008 .
[20] Arash E. Zaghi,et al. Experimental and Analytical Studies of Hospital Piping Assemblies Subjected to Seismic Loading , 2012 .
[21] Ali Bozer,et al. Finding optimal parameters of tuned mass dampers , 2015 .
[22] Alberto Zasso,et al. Active Control in a High-Rise Building under Multidirectional Wind Loads , 2008 .
[23] Robert J. McNamara,et al. Tuned Mass Dampers for Buildings , 1977 .
[24] Jie Liu,et al. Vibration control using ATMD and site measurements on the Shanghai World Financial Center Tower , 2014 .
[26] Proposed Configurations for the Use of Smart Dampers with Bracings in Tall Buildings , 2012 .
[27] Jong-Cheng Wu,et al. Wind tunnel verification of actively controlled high-rise building in along-wind motion , 2002 .
[28] J. Amin,et al. Mean interference effects between two buildings: effects of close proximity , 2011 .
[29] Aly Mousaad Aly,et al. Pressure integration technique for predicting wind-induced response in high-rise buildings , 2013 .
[30] Bijan Samali,et al. Benchmark Problem for Response Control of Wind-Excited Tall Buildings , 2004 .
[31] Bijan Samali,et al. Wind Loading on Tall Buildings , 2007, Electronic Journal of Structural Engineering.
[32] Arash E. Zaghi,et al. Floor Accelerations in Yielding Special Moment Resisting Frame Structures , 2013 .
[33] Roger A. Pielke,et al. Normalized Earthquake Damage and Fatalities in the United States: 1900–2005 , 2009 .
[34] S. Dasgupta. Computation of Rayleigh Damping Coefficients for Large Systems , 2003 .
[35] Ahsan Kareem,et al. Aerodynamic response of structures with parametric uncertainties , 1988 .
[36] Michael Willford,et al. The damped outrigger concept for tall buildings , 2007 .
[37] Aly Mousaad Aly,et al. Proposed approach for determination of tributary areas for scattered pressure taps , 2013 .
[38] Cheng-Wu Chen,et al. Active control for a benchmark building under wind excitations , 2003 .
[39] Yukio Tamura,et al. Damping Evaluation Using Full-Scale Data of Buildings in Japan , 2003 .
[40] Dat Duthinh,et al. Risk Consistency and Synergy in Multihazard Design , 2011 .
[41] Gary C. Hart,et al. Performance‐based wind evaluation and strengthening of existing tall concrete buildings in the Los Angeles region: dampers, nonlinear time history analysis and structural reliability , 2014 .
[42] Yue Li,et al. Review of Methods to Assess, Design for, and Mitigate Multiple Hazards , 2012 .
[43] Alberto Zasso,et al. Dynamics and Control of High-Rise Buildings under Multidirectional Wind Loads , 2011 .
[45] B. D. Mugridge. Literature Review : Noise Characteristics of Axial and Centrifugal Fans as Used in Industry - a Review , 1975 .
[46] D. J. Johns. Wind excited behavior of structures VI , 1979 .
[47] Fujun Peng,et al. An experimental study of active control of wind-induced vibration of super-tall buildings , 2002 .
[48] Yukio Tamura,et al. Amplitude Dependency of Damping in Buildings , 2008 .
[49] A. Aly. Design of buildings for wind and earthquake , 2014 .
[50] Hojjat Adeli,et al. WIND-INDUCED MOTION CONTROL OF 76-STORY BENCHMARK BUILDING USING THE HYBRID DAMPER-TLCD SYSTEM , 2005 .
[51] J. Peterka,et al. Aerodynamic Model Tests of Tall Buildings , 1989 .
[52] Ahsan Kareem,et al. Aerodynamic Loads on Tall Buildings: Interactive Database , 2003 .
[53] Marina Schroder,et al. Structural Control Past Present And Future , 2016 .