Complications of invasive video-EEG monitoring with subdural grid electrodes

Objective: To evaluate the risk factors, type, and frequency of complications during video-EEG monitoring with subdural grid electrodes. Methods: The authors retrospectively reviewed the records of all patients who underwent invasive monitoring with subdural grid electrodes (n = 198 monitoring sessions on 187 patients; median age: 24 years; range: 1 to 50 years) at the Cleveland Clinic Foundation from 1980 to 1997. Results: From 1980 to 1997, the complication rate decreased (p = 0.003). In the last 5 years, 19/99 patients (19%) had complications, including two patients (2%) with permanent sequelae. In the last 3 years, the complication rate was 13.5% (n = 5/37) without permanent deficits. Overall, complications occurred during 52 monitoring sessions (26.3%): infection (n = 24; 12.1%), transient neurologic deficit (n = 22; 11.1%), epidural hematoma (n = 5; 2.5%), increased intracranial pressure (n = 5; 2.5%), and infarction (n = 3; 1.5%). One patient (0.5%) died during grid insertion. Complication occurrence was associated with greater number of grids/electrodes (p = 0.021/p = 0.052; especially >60 electrodes), longer duration of monitoring (p = 0.004; especially >10 days), older age of the patient (p = 0.005), left-sided grid insertion (p = 0.01), and burr holes in addition to the craniotomy (p = 0.022). No association with complications was found for number of seizures, IQ, anticonvulsants, or grid localization. Conclusions: Invasive monitoring with grid electrodes was associated with significant complications. Most of them were transient. Increased complication rates were related to left-sided grid insertion and longer monitoring with a greater number of electrodes (especially more than 60 electrodes). Improvements in grid technology, surgical technique, and postoperative care resulted in significant reductions in the complication rate.

[1]  K D Laxer,et al.  Subdural electrodes for seizure focus localization. , 1986, Neurosurgery.

[2]  A. Olivier Risk and benefit in the surgery of epilepsy: Complications and positive results on seizures tendency and intellectual function , 1988, Acta neurologica Scandinavica. Supplementum.

[3]  R P Lesser,et al.  Subdural Electrodes in the Evaluation for Epilepsy Surgery in Children and Adults , 1988, Neuropediatrics.

[4]  S. Spencer Depth versus subdural electrode studies for unlocalized epilepsy , 1989 .

[5]  M R Sperling,et al.  Comparison of depth and subdural electrodes in recording temporal lobe seizures , 1989, Neurology.

[6]  G. Holmes,et al.  An 8-year experience with depth electrodes in the evaluation of ablative seizure surgery candidates. , 1990, Stereotactic and functional neurosurgery.

[7]  S. Spencer,et al.  Combined depth and subdural electrode investigation in uncontrolled epilepsy , 1990, Neurology.

[8]  D. Ross,et al.  Morbidity associated with subdural electrodes. , 1991, Journal of neurosurgery.

[9]  G Walker,et al.  The morbidity of long-term seizure monitoring using subdural strip electrodes. , 1991, Journal of neurosurgery.

[10]  E Wyllie,et al.  Subdural electrodes in the presurgical evaluation for surgery of epilepsy. , 1992, Epilepsy research. Supplement.

[11]  F. Dubeau,et al.  Morbidity of chronic recording with intracranial depth electrodes in 170 patients. , 1994, Stereotactic and functional neurosurgery.

[12]  U Kramer,et al.  Use of subdural grids and strip electrodes to identify a seizure focus in children. , 1995, Pediatric neurosurgery.

[13]  I. Drury,et al.  Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. , 1996, Neurosurgery.

[14]  B. Swartz,et al.  The safety and efficacy of chronically implanted subdural electrodes: a prospective study. , 1996, Surgical neurology.

[15]  R König,et al.  Surgical and neurological complications in a series of 708 epilepsy surgery procedures. , 1998, Neurosurgery.

[16]  C. Elger,et al.  Safety of Intrahippocampal Depth Electrodes for Presurgical Evaluation of Patients with Intractable Epilepsy , 1997, Epilepsia.

[17]  H. Pannek,et al.  Evaluation with subdural plates in children and adolescents. , 1999, Neurological research.

[18]  Kost Elisevich,et al.  Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy , 1999, Epilepsy Research.

[19]  A 13-Year Experience with Epilepsy Surgery , 2000, Stereotactic and Functional Neurosurgery.