Construction of an Overhauser magnetic gradiometer and the applications in geomagnetic observation and ferromagnetic target localization

The proton precession magnetometer with single sensor is commonly used in geomagnetic observation and magnetic anomaly detection. Due to technological limitations, the measurement accuracy is restricted by several factors such as the sensor performance, frequency measurement precision, instability of polarization module, etc. Aimed to improve the anti-interference ability, an Overhauser magnetic gradiometer with dual sensor structure was designed. An alternative design of a geomagnetic sensor with differential dual-coil structure was presented. A multi-channel frequency measurement algorithm was proposed to increase the measurement accuracy. A silicon oscillator was adopted to resolve the instability of polarization system. This paper briefly discusses the design and development of the gradiometer and compares the data recorded by this instrument with a commonly used commercially Overhauser magnetometer in the world market. The proposed gradiometer records the earth magnetic field in 24 hours with measurement accuracy of ± 0.3 nT and a sampling rate of 3 seconds per sample. The quality of data recorded is excellent and consistent with the commercial instrument. In addition, experiments of ferromagnetic target localization were conducted. This gradiometer shows a strong ability in magnetic anomaly detection and localization. To sum up, it has the advantages of convenient operation, high precision, strong anti-interference, etc., which proves the effectiveness of the dual sensor structure Overhauser magnetic gradiometer.

[1]  Kiwoong Kim,et al.  Proton spin-echo magnetometer: a novel approach for magnetic field measurement in residual field gradient , 2015 .

[2]  S. Tumanski,et al.  Modern magnetic field sensors – a review , 2013 .

[3]  Huan Liu,et al.  Research on a secondary tuning algorithm based on SVD & STFT for FID signal , 2016 .

[4]  Huan Liu,et al.  Noise characterization for the FID signal from proton precession magnetometer , 2017 .

[5]  Huan Liu,et al.  A high precision proton magnetometer based on a multi-channel frequency measurement , 2016, 2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[6]  D. Saveliev,et al.  New vector/scalar Overhauser DNP magnetometers POS-4 for magnetic observatories and directional oil drilling support , 2016 .

[7]  S. Kiselev,et al.  Theodolite-borne vector Overhauser magnetometer: DIMOVER , 2006 .

[8]  Zhang Shuan Design of JPM-1 Proton Magnetometer Based on DSP , 2014 .

[9]  N. Kernevez,et al.  Weak field NMR and EPR spectrometers and magnetometers , 1992, 1992. Digests of Intermag. International Magnetics Conference.

[10]  J. Rutman Characterization of phase and frequency instabilities in precision frequency sources: Fifteen years of progress , 1978, Proceedings of the IEEE.

[11]  Jun Zhu,et al.  Overhauser Geomagnetic Sensor Based on the Dynamic Nuclear Polarization Effect for Magnetic Prospecting , 2016, Sensors.

[12]  Philippe De Smedt,et al.  Removal of sensor tilt noise in fluxgate gradiometer survey data by applying one‐dimensional wavelet filtering , 2017 .

[13]  Yuan Zhou,et al.  Analysis and Decoupling Design of a 30 MHz Resonant SEPIC Converter , 2016, IEEE Transactions on Power Electronics.

[14]  I. Sasada,et al.  Superparamagnetic nanoparticle detection system by using a fundamental mode orthogonal fluxgate (FM-OFG) gradiometer , 2017 .

[15]  Guangyou Fang,et al.  A Fast Calibration Method for Magnetometer Array and the Application of Ferromagnetic Target Localization , 2017, IEEE Transactions on Instrumentation and Measurement.

[16]  N. Kernevez,et al.  Description of a high sensitivity CW scalar DNP-NMR magnetometer , 1991 .

[17]  Hideo Utsumi,et al.  Dynamic nuclear polarization properties of nitroxyl radicals used in Overhauser-enhanced MRI for simultaneous molecular imaging. , 2006, Journal of magnetic resonance.

[18]  A. Denisov,et al.  Broadband mode in proton-precession magnetometers with signal processing regression methods , 2014 .

[19]  C. Chapman,et al.  A high‐stability fluxgate magnetic gradiometer for shallow geophysical survey applications , 2004 .

[20]  J. Shea,et al.  Overhauser dynamic nuclear polarization and molecular dynamics simulations using pyrroline and piperidine ring nitroxide radicals. , 2009, Journal of magnetic resonance.

[21]  Shuang Zhang,et al.  An improved Overhauser magnetometer for Earth's magnetic field observation , 2016, Optical Engineering + Applications.

[22]  Brandon D Armstrong,et al.  A new model for Overhauser enhanced nuclear magnetic resonance using nitroxide radicals. , 2007, The Journal of chemical physics.

[23]  Huan Liu,et al.  A High-Precision Frequency Measurement Algorithm for FID Signal of Proton Magnetometer , 2016, IEEE Transactions on Instrumentation and Measurement.