A multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery.

OBJECTIVE Incisional cerebrospinal fluid (CSF) leakage after cranial surgery is a significant cause of morbidity due to poor wound healing and infection, meningitis, and pseudomeningocele formation. Many common dural closure techniques, such as sutures, autologous grafts, gelatin or collagen sponges, and fibrin glues, are used to achieve watertight closure, although none are US Food and Drug Administration approved for this use. DuraSeal Dural Sealant System is a polyethylene glycol (PEG) hydrogel approved by the U.S. Food and Drug Administration for obtaining watertight dural closure when applied after standard dural suturing. This multicenter, prospective randomized study further evaluated the safety of a PEG hydrogel compared with common dural sealing techniques. METHODS A total of 237 patients undergoing elective cranial surgery at 17 institutions were randomized to dural closure augmented with the PEG hydrogel or a control "standard of care" dural sealing technique after Valsalva maneuver demonstrated an intraoperative nonwatertight dural closure. Data were collected on complications resulting in unplanned postoperative interventions or reoperations, surgical site infections, CSF leaks, and other neurological complications within 30 days. Surgeons also provided data on the ease of use of the dural sealing techniques, as well as preparation and application times. RESULTS The incidences of neurosurgical complications, surgical site infections, and CSF leaks were similar between treatment and control groups, with no statistically significant difference between the measures. In the PEG hydrogel group (n = 120), the incidence of neurosurgical complications was 5.8% (n = 7), the incidence of surgical site infections was 1.7% (n = 2), and the incidence of CSF leak was 0.8% (n = 1). In the control group (n = 117), the incidence of neurosurgical complications was 7.7% (n = 9), the incidence of surgical site infection was 2.6% (n = 3), and the incidence of CSF leak was 1.7% (n = 2). Sealant preparation time was less than 5 minutes in 96.6% of the PEG hydrogel group compared with 66.4% of controls (P < 0.001). The dural augmentation was applied in less than 1 minute in 85.7% of the PEG hydrogel group compared with 66.4% of the control group (P < 0.001). CONCLUSIONS The PEG hydrogel dural sealant used in this study has a similar safety profile to commonly used dural sealing techniques when used as dural closure augmentation in cranial surgery. The PEG hydrogel dural sealant demonstrated faster preparation and application times than other commonly used dural sealing techniques.

[1]  Mark C. Preul,et al.  Toward Optimal Tissue Sealants for Neurosurgery: Use of a Novel Hydrogel Sealant in a Canine Durotomy Repair Model , 2003, Neurosurgery.

[2]  Y Sawamura,et al.  Evaluation of application techniques of fibrin sealant to prevent cerebrospinal fluid leakage: a new device for the application of aerosolized fibrin glue. , 1999, Neurosurgery.

[3]  J. Grotenhuis,et al.  Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair. , 2007, Journal of neurosurgery.

[4]  J. Grotenhuis,et al.  Costs of postoperative cerebrospinal fluid leakage: 1-year, retrospective analysis of 412 consecutive nontrauma cases. , 2005, Surgical neurology.

[5]  H. van Loveren,et al.  The safety and effectiveness of a dural sealant system for use with nonautologous duraplasty materials. , 2010, Journal of neurosurgery.

[6]  W D Spotnitz,et al.  Neurosurgical applications of fibrin glue: augmentation of dural closure in 134 patients. , 1990, Neurosurgery.

[7]  W. Hopfenmüller,et al.  Efficacy and safety of a collagen matrix for cranial and spinal dural reconstruction using different fixation techniques. , 2008, Journal of neurosurgery.

[8]  N. Cohen,et al.  Cerebrospinal Fluid Drainage in the Management of CSF Leak Following Acoustic Neuroma Surgery , 1996, The Laryngoscope.

[9]  M. Samii,et al.  Management of 1000 vestibular schwannomas (acoustic neuromas): surgical management and results with an emphasis on complications and how to avoid them. , 1997, Neurosurgery.

[10]  V. Vanaclocha,et al.  Duraplasty with freeze-dried cadaveric dura versus occipital pericranium for Chiari type I malformation: Comparative study , 2007, Acta Neurochirurgica.

[11]  R. Hoffman Cerebrospinal fluid leak following acoustic neuroma removal , 1994, The Laryngoscope.

[12]  F. Umansky,et al.  The use of fibrin sealant in cerebrospinal fluid leakage , 1991, Neurochirurgia.

[13]  P. Narotam,et al.  A clinicopathological study of collagen sponge as a dural graft in neurosurgery. , 1995, Journal of neurosurgery.

[14]  F. Nataf,et al.  Comparison of Deep Wound Infection Rates Using a Synthetic Dural Substitute (Neuro-Patch) or Pericranium Graft for Dural Closure: A Clinical Review of 1 Year , 2004, Neurosurgery.

[15]  P. Narotam,et al.  Collagen Matrix (DuraGen) in Dural Repair: Analysis of a New Modified Technique , 2004, Spine.

[16]  D. Kong,et al.  Intraoperative management to prevent cerebrospinal fluid leakage after microvascular decompression: dural closure with a “plugging muscle” method , 2007, Neurosurgical Review.

[17]  W. Schievink,et al.  ANAPHYLACTIC REACTIONS TO FIBRIN SEALANT INJECTION FOR SPONTANEOUS SPINAL CSF LEAKS , 2008, Neurology.

[18]  Richard Hayward,et al.  Surgical procedures for posterior fossa tumors in children: does craniotomy lead to fewer complications than craniectomy? , 2002, Journal of neurosurgery.

[19]  Y. Iwasaki,et al.  Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: clinical application to spinal surgery. , 2006, Surgical neurology.

[20]  P. Black,et al.  Cerebrospinal fluid leaks following spinal or posterior fossa surgery: use of fat grafts for prevention and repair. , 2000, Neurosurgical focus.

[21]  E. Kosnik Use of ligamentum nuchae graft for dural closure in posterior fossa surgery. Technical note. , 1998, Journal of neurosurgery.

[22]  R. Hayward,et al.  MRI study of the natural history and risk factors for pseudomeningocoele formation following postfossa surgery in children , 2003, British journal of neurosurgery.

[23]  P. Black Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair. Technical note. , 2002, Journal of neurosurgery.

[24]  N. Cohen,et al.  Autologous fibrin glue in the prevention of cerebrospinal fluid leak following acoustic neuroma surgery. , 1995, The American journal of otology.

[25]  J. Nedzelski,et al.  Cerebrospinal fluid leaks and meningitis in acoustic neuroma surgery , 1991, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[26]  P. Campbell,et al.  Application of a hydrogel sealant improves watertight closures of duraplasty onlay grafts in a canine craniotomy model. , 2007, Journal of neurosurgery.

[27]  T. Beems,et al.  Use of a Novel Absorbable Hydrogel for Augmentation of Dural Repair: Results of a Preliminary Clinical Study , 2005, Neurosurgery.

[28]  Khoi D. Than,et al.  POLYETHYLENE GLYCOL HYDROGEL DURAL SEALANT MAY REDUCE INCISIONAL CEREBROSPINAL FLUID LEAK AFTER POSTERIOR FOSSA SURGERY , 2008 .