Typical microCT systems for in vivo small animal imaging have a total acquisition time on the order of 10 minutes for a single scan, with the detector read-out time often a major contributor to acquisition length. Reduction of the portion of the scan time spent in read-out can be achieved through short-scan acquisition. Knowledge of and correction for geometric misalignments is another crucial factor in obtaining high quality microCT images. In this work, we have implemented a short-scan Feldkamp algorithm with correction geometric misalignment. Due to our system misalignments, severe ghosting artifacts are present in the reconstruction. We have implemented a reconstruction algorithm with correction for the misalignments which eliminates the ghosting artifacts. Comparisons of full-scan and short-scan reconstructions of both phantom and mouse data show similar image quality. We have also compared short-scan reconstructions to full-scan reconstructions from projection data with roughly the same total acquisition time. In this case, blurring is visible in sagittal slices of the full-scan reconstructions that is not present in the short-scan reconstructions. Short-scan acquisition provides reduction of the total acquisition time resulting in microCT images without the loss in image quality obtained by simply reducing the number of projections for a full-scan acquisition. Axis of rotation horizontal transversal off-center shift and the X-ray source horizontal transversal shift are the most sensitive parameters.
[1]
K Engelke,et al.
Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates.
,
2001,
Medical physics.
[2]
Eric C Frey,et al.
Development of a 4-D digital mouse phantom for molecular imaging research.
,
2004,
Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.
[3]
Y. Liu,et al.
Half-scan cone-beam x-ray microtomography formula.
,
2008,
Scanning.
[4]
D. Parker.
Optimal short scan convolution reconstruction for fan beam CT
,
1982
.
[5]
Gengsheng Lawrence Zeng,et al.
A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography
,
1992,
IEEE Trans. Medical Imaging.
[6]
L. Feldkamp,et al.
Practical cone-beam algorithm
,
1984
.
[7]
Eric C. Frey,et al.
Development and evaluation of a MicroCT system for small animal imaging
,
2001,
2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).
[8]
D L Parker,et al.
Optimal short scan convolution reconstruction for fanbeam CT.
,
1982,
Medical physics.