Myelin water imaging from multi-echo T 2 MR relaxometry data using a joint sparsity constraint

Demyelination is the key pathological process in multiple sclerosis (MS). The extent of demyelination can be quantified with magnetic resonance imaging by assessing the myelin water fraction (MWF). However, long computation times and high noise sensitivity hinder the translation of MWF imaging to clinical practice. In this work, we introduce a more efficient and noise robust method to determine the MWF using a joint sparsity constraint and a pre-computed B1+-T2 dictionary. A single component analysis with this dictionary is used in an initial step to obtain a B1+ map. The T2 distribution is then determined from a reduced dictionary corresponding to the estimated B1+ map using a combination of a non-negativity and a joint sparsity constraint. The non-negativity constraint ensures that a feasible solution with non-negative contribution of each T2 component is obtained. The joint sparsity constraint restricts the T2 distribution to a small set of T2 relaxation times shared between all voxels and reduces the noise sensitivity. The applied Sparsity Promoting Iterative Joint NNLS (SPIJN) algorithm can be implemented efficiently, reducing the computation time by a factor of 50 compared to the commonly used regularized non-negative least squares algorithm. The proposed method was validated in simulations and in 8 healthy subjects with a 3D multi-echo gradient- and spin echo scan at 3T. In simulations, the absolute error in the MWF decreased from 0.031 to 0.013 compared to the regularized NNLS algorithm for SNR=250. The in vivo results were consistent with values reported in literature and improved MWF-quantification was obtained especially in the frontal white matter. The maximum standard deviation in mean MWF in different regions of interest between subjects was smaller for the proposed method (0.0193) compared to the regularized NNLS algorithm (0.0266). In conclusion, the proposed method for MWF estimation is less computationally expensive and less susceptible to noise compared to state of the art methods. These improvements might be an important step towards clinical translation of MWF measurements.

[1]  A. Mackay,et al.  In vivo measurement of T2 distributions and water contents in normal human brain , 1997, Magnetic resonance in medicine.

[2]  Vikas Gulani,et al.  Bayesian estimation of multicomponent relaxation parameters in magnetic resonance fingerprinting , 2018, Magnetic resonance in medicine.

[3]  M. Yuan,et al.  Model selection and estimation in regression with grouped variables , 2006 .

[4]  C. Laule,et al.  Water content and myelin water fraction in multiple sclerosis , 2004, Journal of Neurology.

[5]  Roger C. Tam,et al.  Myelin water imaging data analysis in less than one minute , 2020, NeuroImage.

[6]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[7]  Petre Stoica,et al.  Parameter estimation of exponential signals: A system identification approach , 2013, Digit. Signal Process..

[8]  C. S. Poon,et al.  Practical T2 quantitation for clinical applications , 1992, Journal of magnetic resonance imaging : JMRI.

[9]  C. Laule,et al.  Long T2 water in multiple sclerosis: What else can we learn from multi-echo T2 relaxation? , 2007, Journal of Neurology.

[10]  Charles L. Lawson,et al.  Solving least squares problems , 1976, Classics in applied mathematics.

[11]  Dwight G Nishimura,et al.  A robust methodology for in vivo T1 mapping , 2010, Magnetic resonance in medicine.

[12]  Petre Stoica,et al.  A multicomponent T2 relaxometry algorithm for myelin water imaging of the brain , 2016, Magnetic resonance in medicine.

[13]  A. MacKay,et al.  Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin , 2016, Brain plasticity.

[14]  Yiping P. Du,et al.  Improved myelin water quantification using spatially regularized non‐negative least squares algorithm , 2009, Journal of magnetic resonance imaging : JMRI.

[15]  William E. Caplin Criteria for Analysis , 2011 .

[16]  Mike E. Davies,et al.  Fast Non-Negative Orthogonal Matching Pursuit , 2015, IEEE Signal Processing Letters.

[17]  Srikantan S. Nagarajan,et al.  Iterative Reweighted l1 and l2 Methods for Finding Sparse Solution , 2016 .

[18]  Craig K. Jones,et al.  Applications of stimulated echo correction to multicomponent T2 analysis , 2012, Magnetic resonance in medicine.

[19]  Susan A. Gauthier,et al.  Multi-Compartment T2 Relaxometry Using a Spatially Constrained Multi-Gaussian Model , 2014, PloS one.

[20]  Ravinder Reddy,et al.  Using 3D spatial correlations to improve the noise robustness of multi component analysis of 3D multi echo quantitative T2 relaxometry data , 2018, NeuroImage.

[21]  Charles Soussen,et al.  An optimized version of non-negative OMP , 2017 .

[22]  Sunli Tang,et al.  Multicompartment magnetic resonance fingerprinting , 2018, Inverse problems.

[23]  Mariya Doneva,et al.  Compressed sensing reconstruction for magnetic resonance parameter mapping , 2010, Magnetic resonance in medicine.

[24]  D. Feinberg,et al.  GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique , 1991, Magnetic resonance in medicine.

[25]  Mark D. Does,et al.  Inferring brain tissue composition and microstructure via MR relaxometry , 2018, NeuroImage.

[26]  Jacobus F. A. Jansen,et al.  A new analysis approach for T2 relaxometry myelin water quantification: Orthogonal Matching Pursuit , 2018, Magnetic resonance in medicine.

[27]  A. MacKay,et al.  In vivo visualization of myelin water in brain by magnetic resonance , 1994, Magnetic resonance in medicine.

[28]  Noam Shemesh,et al.  Evaluation of principal component analysis image denoising on multi‐exponential MRI relaxometry , 2019, Magnetic resonance in medicine.

[29]  Mariya Doneva,et al.  Fast multi‐component analysis using a joint sparsity constraint for MR fingerprinting , 2019, Magnetic resonance in medicine.

[30]  J. Sedlacik,et al.  Heterogeneity of Multiple Sclerosis Lesions in Multislice Myelin Water Imaging , 2016, PloS one.

[31]  Christian EL HAJJ,et al.  Multi-Exponential Relaxation Times Maps Reconstruction and Unsupervised Classification in Magnitude Magnetic Resonance Imaging , 2019, 2019 27th European Signal Processing Conference (EUSIPCO).

[32]  Irene M. Vavasour,et al.  Non-negative least squares fitting of multi-exponential T2 decay data: Are we able to accurately measure the fraction of myelin water? , 2019 .

[33]  Simon K. Warfield,et al.  T 2-Relaxometry for Myelin Water Fraction Extraction Using Wald Distribution and Extended Phase Graph , 2014, MICCAI.

[34]  Mark Griswold,et al.  Fast cardiac T1 mapping in mice using a model‐based compressed sensing method , 2012, Magnetic resonance in medicine.

[35]  Alex L. MacKay,et al.  Quantitative interpretation of NMR relaxation data , 1989 .

[36]  Tobias Kober,et al.  MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field , 2010, NeuroImage.

[37]  J. Hennig Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes , 1991 .

[38]  David P. Wipf,et al.  Iterative Reweighted 1 and 2 Methods for Finding Sparse Solutions , 2010, IEEE J. Sel. Top. Signal Process..

[39]  B. Mädler,et al.  MR evidence of long T2 water in pathological white matter , 2007, Journal of magnetic resonance imaging : JMRI.

[40]  Julien Cohen-Adad,et al.  Inter-Vendor Reproducibility of Myelin Water Imaging Using a 3D Gradient and Spin Echo Sequence , 2018, Front. Neurosci..

[41]  G. B. Pike,et al.  Reproducibility of in vivo magnetic resonance imaging–based measurement of myelin water , 2010, Journal of magnetic resonance imaging : JMRI.

[42]  Gerhard S. Drenthen,et al.  Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration , 2019, NeuroImage.

[43]  Anthony Traboulsee,et al.  Long T 2 water in multiple sclerosis: What else can we learn from multi-echo T 2 , 2007 .

[44]  B. Mädler,et al.  Multicenter measurements of myelin water fraction and geometric mean T2: Intra‐ and intersite reproducibility , 2013, Journal of magnetic resonance imaging : JMRI.

[45]  Youngjin Yoo,et al.  Fast computation of myelin maps from MRI T2 relaxation data using multicore CPU and graphics card parallelization , 2015, Journal of magnetic resonance imaging : JMRI.

[46]  Daniel K Sodickson,et al.  Rapid and accurate T2 mapping from multi–spin‐echo data using Bloch‐simulation‐based reconstruction , 2015, Magnetic resonance in medicine.

[47]  J. Duerk,et al.  Magnetic Resonance Fingerprinting , 2013, Nature.

[48]  R M Henkelman,et al.  Diffusional anisotropy of T2 components in bovine optic nerve , 1998, Magnetic resonance in medicine.

[49]  Jieun Lee,et al.  Artificial neural network for myelin water imaging , 2019, Magnetic resonance in medicine.

[50]  M. Bronskill,et al.  Criteria for analysis of multicomponent tissue T2 relaxation data , 1996, Magnetic resonance in medicine.

[51]  Alex L. MacKay,et al.  Rapid whole cerebrum myelin water imaging using a 3D GRASE sequence , 2012, NeuroImage.

[52]  C. Lawson,et al.  Solving least squares problems , 1976, Classics in applied mathematics.

[53]  J. Sedlacik,et al.  Noise robust spatially regularized myelin water fraction mapping with the intrinsic B1‐error correction based on the linearized version of the extended phase graph model , 2016, Journal of magnetic resonance imaging : JMRI.