A SELF-CALIBRATION METHOD FOR ARTICULATED ARM COORDINATE MEASURING MACHINES

To improve the accuracy of articulated arm coordinate measuring machines (AACMM) and simplify the calibration process, an improved self-calibration method was proposed. Unlike the traditional calibration methods, which need external expensive precision instruments and elaborate setups, the proposed self-calibration method only requires a gauge to assist the data acquisition operation. By designing a movement trajectory of the AACMM, a series of joint angles can be obtained to form overdetermined equations based on the kinematic model of the AACMM. Therefore, the structural parameters of the AACMM can be obtained by solving the equations. Consequently, the calibration can be achieved by solving these equations. The coefficient matrix of the equations was further analyzed to simplify the equations, and a constructive method was presented to identify the structural parameters by solving the simplified equations with a modified simulated annealing algorithm, in which an optimized search strategy was applied t...

[1]  Zichen Chen,et al.  A Novel Articulated Arm Coordinate Measuring Machine with Variable Length Links , 2012 .

[2]  Wen Wang,et al.  Study on the Error Transfer of Articulated Arm Coordinate Measuring Machines , 2013 .

[3]  González-Madruga Daniel,et al.  Influence of human factor in the AACMM performance: a new evaluation methodology , 2014 .

[4]  Eduardo Cuesta,et al.  Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines , 2013, Sensors.

[5]  Hiroyuki Hamana,et al.  Calibration of Articulated Arm Coordinate Measuring Machine Considering Measuring Posture , 2011, Int. J. Autom. Technol..

[6]  Igor Kovac,et al.  Testing and calibration of coordinate measuring arms , 2001 .

[7]  J. Denavit,et al.  A kinematic notation for lower pair mechanisms based on matrices , 1955 .

[8]  Jorge Santolaria,et al.  Verification of an articulated arm coordinate measuring machine using a laser tracker as reference equipment and an indexed metrology platform , 2015 .

[9]  Yaoxin Zhang,et al.  Self-calibration for kinematic parameters of a redundant planar two-degree-of-freedom parallel manipulator using evolutionary algorithms , 2009 .

[10]  Bo Chen,et al.  The calibration and error compensation techniques for an Articulated Arm CMM with two parallel rotational axes , 2013 .

[11]  Zehui Shao,et al.  An Effective Simulated Annealing Algorithm for Solving the Traveling Salesman Problem , 2009 .

[12]  Guanbin Gao,et al.  Analysis and Compensation of Installation Errors for Circular Grating Angle Sensors , 2011 .

[13]  Jorge Santolaria,et al.  Articulated Arm Coordinate Measuring Machine Calibration by Laser Tracker Multilateration , 2014, TheScientificWorldJournal.

[14]  Min Ge,et al.  Methodology for the assessment of measuring uncertainties of articulated arm coordinate measuring machines , 2014 .