Selective homonuclear Hartmann–Hahn transfer method for in vivo spectral editing in the human brain

A novel selective homonuclear Hartmann–Hahn transfer method for in vivo spectral editing is proposed and applied to measurements of γ‐aminobutyric acid (GABA) in the human brain at 3 T. The proposed method utilizes a new concept for in vivo spectral editing, the spectral selectivity of which is not based on a conventional editing pulse but based on the stringent requirement of the doubly selective Hartmann–Hahn match. The sensitivity and spectral selectivity of GABA detection achieved by this doubly selective Hartmann–Hahn match scheme was superior to that achievable by conventional in vivo spectral editing techniques providing both sensitivity enhancement and excellent suppression of overlapping resonances in a single shot. Since double‐quantum filtering gradients were not employed, singlets such as the NAA methyl group at 2.02 ppm and the creatine methylene group at 3.92 ppm were detected simultaneously. These singlets may serve as navigators for the spectral phase of GABA and for frequency shifts during measurements. The estimated concentration of GABA in the frontoparietal region of the human brain in vivo was 0.7 ± 0.2 μmol/g (mean ± SD, n = 12). Magn Reson Med 53:503–510, 2005. Published 2005 Wiley‐Liss, Inc.

[1]  Jun Shen,et al.  In vivo detection of gray and white matter differences in GABA concentration in the human brain , 2006, NeuroImage.

[2]  Jun Shen,et al.  In vivo single-shot three-dimensionally localized multiple quantum spectroscopy of GABA in the human brain with improved spectral selectivity. , 2005, Journal of magnetic resonance.

[3]  L. Kevin,et al.  Localized 1 H NMR measurements of y-aminobutyric acid in human brain in vivo , 2005 .

[4]  Jun Shen,et al.  A new strategy for in vivo spectral editing. Application to GABA editing using selective homonuclear polarization transfer spectroscopy. , 2004, Journal of magnetic resonance.

[5]  Hellmut Merkle,et al.  Single‐shot two‐echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo , 2004, Magnetic resonance in medicine.

[6]  Rolf Gruetter,et al.  Measurement of reduced glutathione (GSH) in human brain using LCModel analysis of difference‐edited spectra , 2003, Magnetic resonance in medicine.

[7]  C. Hanstock,et al.  GABA X2 multiplet measured pre‐ and post‐administration of vigabatrin in human brain , 2002, Magnetic resonance in medicine.

[8]  Rolf Gruetter,et al.  Direct in vivo measurement of human cerebral GABA concentration using MEGA‐editing at 7 Tesla , 2002, Magnetic resonance in medicine.

[9]  Jun Shen,et al.  In vivo GABA editing using a novel doubly selective multiple quantum filter , 2002, Magnetic resonance in medicine.

[10]  G. Bloch,et al.  Brain GABA editing without macromolecule contamination , 2001, Magnetic resonance in medicine.

[11]  H. Lei,et al.  A localized double‐quantum filter for in vivo detection of taurine , 1999, Magnetic resonance in medicine.

[12]  P Boesiger,et al.  Detection of glutathione in the human brain in vivo by means of double quantum coherence filtering , 1999, Magnetic resonance in medicine.

[13]  Douglas L. Rothman,et al.  In vivo chemical shift imaging of γ‐aminobutyric acid in the human brain , 1999 .

[14]  D. Rothman,et al.  In vivo chemical shift imaging of gamma-aminobutyric acid in the human brain. , 1999, Magnetic resonance in medicine.

[15]  Jun Shen,et al.  In vivo lactate and β‐hydroxybutyrate editing using a pure‐phase refocusing pulse train , 1998, Magnetic resonance in medicine.

[16]  Jullie W Pan,et al.  Measurements of human cerebral GABA at 4.1 T using numerically optimized editing pulses , 1998, Magnetic resonance in medicine.

[17]  P F Renshaw,et al.  In vivo detection of GABA in human brain using a localized double‐quantum filter technique , 1997, Magnetic resonance in medicine.

[18]  P F Renshaw,et al.  A technique for detecting GABA in the human brain with PRESS localization and optimized refocusing spectral editing radiofrequency pulses , 1996, Magnetic resonance in medicine.

[19]  Jun Shen Doubly Selective HeteronuclearJCross Polarization and Its Applications to the Measurement of Long-Range1H–13C Coupling Constants , 1996 .

[20]  A. Wilman,et al.  Same-scan acquisition of both edited J-coupled multiplets and singlet resonances of uncoupled spins for proton MRS. , 1995, Journal of magnetic resonance. Series B.

[21]  P. V. van Zijl,et al.  Single-scan in vivo lactate editing with complete lipid and water suppression by selective multiple-quantum-coherence transfer (Sel-MQC) with application to tumors. , 1995, Journal of magnetic resonance. Series B.

[22]  K. Behar,et al.  Analysis of macromolecule resonances in 1H NMR spectra of human brain , 1994, Magnetic resonance in medicine.

[23]  R. Freeman,et al.  Techniques for Multisite Excitation , 1993 .

[24]  R. Mattson,et al.  Localized 1H NMR measurements of gamma-aminobutyric acid in human brain in vivo. , 1993, Proceedings of the National Academy of Sciences of the United States of America.

[25]  H. Schwalbe,et al.  Exclusive tailored correlation spectroscopy (E.TACSY) , 1993 .

[26]  R Gruetter,et al.  Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils , 1993, Magnetic resonance in medicine.

[27]  G. Bodenhausen,et al.  Separation of Overlapping Multiplets in Two‐Dimensional NMR Spectra by Selective “Injection” of Magnetization , 1992 .

[28]  G. Bodenhausen,et al.  Coherence transfer in nuclear magnetic resonance by selective homonuclear Hartmann-Hahn correlation spectroscopy , 1991 .

[29]  R G Shulman,et al.  1H homonuclear editing of rat brain using semiselective pulses. , 1985, Proceedings of the National Academy of Sciences of the United States of America.

[30]  Richard R. Ernst,et al.  Coherence transfer by isotropic mixing: Application to proton correlation spectroscopy , 1983 .