Design analysis of single-sided natural ventilation

Natural ventilation is an effective measure to save energy consumed in buildings and to improve indoor air quality. This investigation studied single-sided natural ventilation by using a computational fluid dynamics (CFD) model, together with analytical and empirical models. The CFD model was applied to determine the effects of buoyancy, wind, or their combination on ventilation rates and indoor conditions. For buoyancy-driven flow, the CFD results are within a 10% difference from the semi-analytical results. For combined wind- and buoyancy-driven flow, CFD may have underpredicted the empirical model results by approximately 25%. This investigation also studied the effects of opposing buoyancy and wind forces.

[1]  Jeremy Cockroft,et al.  Ventilation of an Enclosure Through a Single Opening , 1976 .

[2]  A. Lahellec,et al.  Modelling natural convection in a heated vertical channel for room ventilation , 2000 .

[3]  D. W. Etheridge Unsteady flow effects due to fluctuating wind pressures in natural ventilation design—instantaneous flow rates , 2000 .

[4]  Muriel Regard-Alchakkif,et al.  Ventilation naturelle d'un local par une grande ouverture extérieure : Calcul à l'aide d'un code de champ , 1998 .

[5]  M. Sandberg,et al.  Building Ventilation: Theory and Measurement , 1996 .

[6]  Hazim B. Awbi,et al.  Air movement in naturally-ventilated buildings , 1996 .

[7]  C A Pickering,et al.  The sick building syndrome: prevalence studies. , 1984, British medical journal.

[8]  Mattheos Santamouris,et al.  On the combination of air velocity and flow measurements in single sided natural ventilation configurations , 1996 .

[9]  Z. D. Chen,et al.  Buoyancy-driven displacement natural ventilation in a single-zone building with three-level openings , 2002 .

[10]  L. Meskin,et al.  Breath of fresh air. , 1996, Nursing standard (Royal College of Nursing (Great Britain) : 1987).

[11]  Yuguo Li,et al.  Buoyancy-driven natural ventilation in a thermally stratified one-zone building , 2000 .

[12]  Gennady Ziskind,et al.  Ventilation by natural convection of a one-story building , 2002 .

[13]  T Willmert The return of natural ventilation. , 2001, Architectural record.

[14]  G. J. Levermore The exponential limit to the cooling of buildings by natural ventilation , 2002 .

[15]  Simos Yannas,et al.  Climate Responsive Architecture , 2002 .

[16]  D. W. Etheridge,et al.  Direct wind tunnel modelling of natural ventilation for design purposes , 1999 .

[17]  Joseph Khedari,et al.  New configurations of a roof solar collector maximizing natural ventilation , 2001 .

[18]  Francis Allard,et al.  Natural ventilation in buildings : a design handbook , 1998 .

[19]  S. Orszag,et al.  Development of turbulence models for shear flows by a double expansion technique , 1992 .

[20]  D. W. Etheridge,et al.  Measurements of turbulent flow downstream of a rearward-facing step , 1978, Journal of Fluid Mechanics.

[21]  Qingyan Chen,et al.  Prediction of room air motion by Reynolds-stress models , 1996 .

[22]  Qingyan Chen,et al.  Effect of fluctuating wind direction on cross natural ventilation in buildings from large eddy simulation , 2002 .

[23]  Chris T. Kiranoudis,et al.  Numerical simulation of air flow field in single-sided ventilated buildings , 2000 .

[24]  J. Busch A tale of two populations: thermal comfort in air-conditioned and naturally ventilated offices in Thailand , 1992 .

[25]  Qingyan Chen COMPARISON OF DIFFERENT k-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONS , 1995 .

[26]  Guohui Gan,et al.  Effective depth of fresh air distribution in rooms with single-sided natural ventilation , 2000 .