Dynamic Ventilation $^3$He MRI for the Quantification of Disease in the Rat Lung

Pulmonary diseases are known to be largely inhomogeneous. To evaluate such inhomogeneities, we are testing an image-based method to measure gas flow in the lung regionally. Dynamic, spin-density-weighted hyperpolarized 3He MR images performed during slow inhalation of this gas were analyzed to quantify regional inflation rate. This parameter was measured in regions of interest (ROIs) that were defined by a rectangular grid that covered the entire rat lung and grew dynamically with it during its inflation. We used regional inflation rate to quantify elastase-induced emphysema and to differentiate healthy ( n = 8) from elastase-treated ( n = 9) rat lungs as well as healthy from elastase-treated areas of one rat unilaterally treated with elastase in the left lung. Emphysema was also assessed by gold standard morphological and well-established hyperpolarized 3He MRI diffusion measurements. Mean values of regional inflation rates were significantly different for healthy and elastase-treated animals and correlated well with the apparent diffusion coefficient of 3He and morphological measurements. The image-based biomarker inflation rate may be useful for the assessment of regional lung ventilation.

[1]  A. Sukstanskii,et al.  3He diffusion MRI of the lung. , 2005, Academic radiology.

[2]  S. Kelsen,et al.  Effect of elastase-induced emphysema on the force-generating ability of the diaphragm. , 1982, The Journal of clinical investigation.

[3]  H. Kauczor,et al.  Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement , 2008, Investigative radiology.

[4]  G Allan Johnson,et al.  Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI , 2003, Magnetic resonance in medicine.

[5]  J. M. Pérez-Sánchez,et al.  A fully MRI‐compatible animal ventilator for special‐gas mixing applications , 2005 .

[6]  S. Shapiro,et al.  Animal models for COPD. , 2000, Chest.

[7]  H. Kauczor,et al.  Dynamic Ventilation 3He-Magnetic Resonance Imaging With Lung Motion Correction: Gas Flow Distribution Analysis , 2002, Investigative radiology.

[8]  A. Troyer Effect of hyperinflation on the diaphragm , 1997 .

[9]  Yannick Crémillieux,et al.  Dynamic 3He imaging for quantification of regional lung ventilation parameters , 2003, Magnetic resonance in medicine.

[10]  K. Minard,et al.  3D 3He diffusion MRI as a local in vivo morphometric tool to evaluate emphysematous rat lungs. , 2008, Journal of applied physiology.

[11]  J M Wild,et al.  Functional magnetic resonance imaging of the lung. , 2003, British journal of anaesthesia.

[12]  Eduard E de Lange,et al.  MRI of the lungs using hyperpolarized noble gases , 2002, Magnetic resonance in medicine.

[13]  Edwin J R van Beek,et al.  Hyperpolarized 3-helium magnetic resonance imaging to probe lung function. , 2005, Proceedings of the American Thoracic Society.

[14]  G. Snider,et al.  Respiratory mechanics in hamsters following treatment with endotracrael elastase or collagenase. , 1977, Journal of applied physiology: respiratory, environmental and exercise physiology.

[15]  Dmitriy A Yablonskiy,et al.  Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema , 2006, Magnetic resonance in medicine.

[16]  Edwin J R van Beek,et al.  Dynamic radial projection MRI of inhaled hyperpolarized 3He gas , 2003, Magnetic resonance in medicine.

[17]  Grace Parraga,et al.  Imaging of lung function using hyperpolarized helium‐3 magnetic resonance imaging: Review of current and emerging translational methods and applications , 2010, Journal of magnetic resonance imaging : JMRI.

[18]  S. Patz,et al.  Hyperpolarized gas MR Imaging of the lung: current status as a research tool. , 2009, Journal of thoracic imaging.

[19]  K. Sigaloff,et al.  Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging , 2000, NMR in biomedicine.

[20]  John W. Eaton,et al.  GNU Octave Manual Version 3 , 2008 .

[21]  V. Callot,et al.  Helium-3 MRI diffusion coefficient: correlation to morphometry in a model of mild emphysema , 2003, European Respiratory Journal.

[22]  Edwin J R van Beek,et al.  Quantitative analysis of regional airways obstruction using dynamic hyperpolarized 3He MRI—Preliminary results in children with cystic fibrosis , 2005, Journal of magnetic resonance imaging : JMRI.

[23]  Ignacio Rodríguez,et al.  A MRI and Polarized Gases Compatible Respirator and Gas Administrator for the Study of the Small Animal Lung: Volume Measurement and Control , 2010, IEEE Transactions on Biomedical Engineering.

[24]  L W Hedlund,et al.  Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[25]  James R. Brookeman,et al.  Physiological Imaging of the Lung Evaluation of emphysema severity and progression in a rabbit model : comparison of hyperpolarized 3 He and 129 Xe diffusion MRI with lung morphometry , 2007 .

[26]  Arnab Majumdar,et al.  Quantitative characterization of airspace enlargement in emphysema. , 2006, Journal of applied physiology.

[27]  P. Adeleine,et al.  Quantitative measurements of regional lung ventilation using helium‐3 MRI in a methacholine‐induced bronchoconstriction model , 2006, Journal of magnetic resonance imaging : JMRI.

[28]  M Salerno,et al.  Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3He: Preliminary studies in healthy and diseased lungs , 2001, Magnetic resonance in medicine.