Increased tissue water in patients with severe sepsis affects tissue oxygenation measured by near-infrared spectroscopy: a prospective, observational case-control study

Background Tissue oedema affects tissue perfusion and interferes with the monitoring of tissue oxygenation in patients with severe sepsis. However, the underlying mechanisms remain unclear. We used a wireless near-infrared spectroscopy (NIRS) device that transmits tri-wavelength light to quantify tissue haemoglobin (Hb) and water (H2O) content. We estimated tissue H2O in severe sepsis patients and healthy controls, compared their difference, and investigated the correlation of tissue H2O with systemic haemodynamics and its impact on tissue oxygenation. Methods Seventy-seven adult patients with new-onset severe sepsis admitted to the intensive care unit within 72 h and 30 healthy volunteers (controls) were enrolled. The NIRS device was placed on the participant’s leg to estimate the relative tissue concentrations of oxy-Hb ([HbO2]), deoxy-Hb ([HbR]), total Hb ([HbT]), and H2O ([H2O]) at rest for three consecutive days. Two-sample t-test or Mann-Whitney U test, chi-square test, and generalised estimating equations (GEEs) were used for comparisons. Results In severe sepsis patients, the [H2O] in the anterior tibia was higher [mean (standard deviation, 95% confidence interval), 10.57 (3.37, 9.81–11.34) vs. 7.40 (1.89, 6.70–8.11)] and the [HbO2], [HbT], and tissue Hb oxygen saturation (StO2) were lower [0.20 (0.01, 0.20–0.20) vs. 0.22 (0.01, 0.22–0.23), 0.42 (0.02, 0.42–0.43) vs. 0.44 (0.02, 0.44–0.45), and 47.25% (1.97%, 46.80–47.70%) vs. 49.88% (1.26%, 49.41–50.35%), respectively] than in healthy controls in first-day measurements. GEE analysis revealed significant differences in [H2O], [HbO2], [HbT], and StO2 between groups over three consecutive days (all P≤0.001). In addition, [HbO2] and StO2 levels gradually decreased over time in the patient group. A negative correlation was observed between [H2O] and [HbO2] and StO2, which became more obvious over time (day 1: r=−0.51 and r=−0.42, respectively; both P<0.01; day 3: r=−0.67 and r=−0.63, respectively, both P<0.01). Systolic arterial pressure was positively related to [H2O] (r=0.51, P<0.05, on day 1) but was not associated with tissue oxygenation parameters. Conclusions NIRS can be used to quantify tissue H2O. Severe sepsis patients have increased tissue H2O, which responds to changes in arterial blood pressure and affects tissue oxygenation.