Chemical sensing using a polymer coated long-period fiber grating interrogated by ring-down spectroscopy

Abstract An etched long-period grating was used as a refractive index sensor for vapours of four volatile organic compounds, i.e. m-xylene, cyclohexane, trichloroethylene and commercial gasoline. The sensitivity to the vapours was further increased by solid-phase microextraction into a coating made of polydimethylsiloxane (PDMS)/polymethyl-octylsiloxane (PMOS) co-polymer. By further amplification of the optical loss in an optical cavity made of two identical fiber-Bragg gratings and interrogation by phase-shift cavity ring-down spectroscopy we could detect and distinguish xylene (detection limit: 134 ppm) from trichloroethylene (3300 ppm), cyclohexane (1850 ppm) and gasoline (10,500 ppm).

[1]  A. Buosciolo,et al.  Long period grating working in transition mode as promising technological platform for label-free biosensing. , 2009, Optics express.

[2]  J S Sirkis,et al.  Evanescent wave long-period fiber bragg grating as an immobilized antibody biosensor. , 2000, Analytical chemistry.

[3]  Hans-Peter Loock,et al.  Fiber-loop ring-down spectroscopy , 2002 .

[4]  Tao Wei,et al.  Zeolite thin film-coated long period fiber grating sensor for measuring trace organic vapors , 2009 .

[5]  Hypolito José Kalinowski,et al.  Fiber optic sensors for hydrocarbon detection , 2005 .

[6]  Paul V. Roberts,et al.  A critical review of Henry's law constants for environmental applications , 1996 .

[7]  Temperature and strain sensor based on weak LPG and fiber ring down , 2008 .

[8]  Kin Seng Chiang,et al.  Analysis of etched long-period fibre grating and its response to external refractive index , 2000 .

[9]  A. Vengsarkar,et al.  Optical fiber long-period grating sensors. , 1996, Optics letters.

[10]  Nicholas R. Trefiak,et al.  Ringdown spectroscopy in optical waveguides , 2007 .

[11]  Alan D. Kersey,et al.  Analysis of the response of long period fiber gratings to external index of refraction , 1998 .

[12]  David J. Webb,et al.  Biochemical sensor based on a novel all-fibre cavity ring down spectroscopy technique incorporating a tilted fibre Bragg grating , 2006 .

[13]  A. O’Keefe,et al.  Cavity ring‐down optical spectrometer for absorption measurements using pulsed laser sources , 1988 .

[14]  Daniel E Vogler,et al.  Fiber-optic cavity sensing of hydrogen diffusion. , 2003, Applied optics.

[15]  Anbo Wang,et al.  Fibre-optic interferometric immuno-sensor using long period grating , 2006 .

[16]  C. Crudden,et al.  Chemical sensor based on a long-period fibre grating modified by a functionalized polydimethylsiloxane coating. , 2008, The Analyst.

[17]  S. B. Lee,et al.  Displacements of the resonant peaks of a long-period fiber grating induced by a change of ambient refractive index. , 1997, Optics letters.

[18]  S. James,et al.  Optical fibre long-period grating sensors: characteristics and application , 2003 .

[19]  V. Bhatia Applications of long-period gratings to single and multi-parameter sensing. , 1999, Optics express.

[20]  Tuomo von Lerber,et al.  Cavity-ring-down principle for fiber-optic resonators: experimental realization of bending loss and evanescent-field sensing. , 2002, Applied optics.

[21]  K. Plett Development and Characterization of Polysiloxane Polymer Films for Use in Optical Sensor Technology , 2008 .

[22]  Hans-Peter Loock,et al.  Phase-shift fiber-loop ring-down spectroscopy. , 2004, Analytical chemistry.

[23]  Scott S.-H. Yam,et al.  Measurement of multi-exponential optical decay processes by phase-shift cavity ring-down , 2009 .