Voltage control in a DFIG-DC system connected to a stand-alone dc load

This paper proposes a control scheme for a stand-alone DFIG-DC system where the stator and the rotor are connected to a dc load by an uncontrolled diode bridge and a VSI respectively. The stator frequency and the dc voltage regulation are achieved by a field oriented control, however, with respect to the classical ac stand alone DFIG, the role of the rotor currents is swapped, namely: the d-axis and q-axis rotor currents are used for the frequency and for the dc voltage regulation respectively. Such a choice is due to the peculiarity of the operation of the diode bridge connected to a constant voltage dc link. The control scheme is presented and design criteria for the voltage controller are reported. The performances of the system are verified by simulations.

[1]  G. D. Marques,et al.  Stator Frequency Regulation in a Field-Oriented Controlled DFIG Connected to a DC Link , 2014, IEEE Transactions on Industrial Electronics.

[2]  Gil D. Marques,et al.  A Scheme for the Power Control in a DFIG Connected to a DC Bus via a Diode Rectifier , 2015, IEEE Transactions on Power Electronics.

[3]  Matteo F. Iacchetti,et al.  Inner Control Method and Frequency Regulation of a DFIG Connected to a DC Link , 2014, IEEE Transactions on Energy Conversion.

[4]  Gil D. Marques,et al.  Operation and design issues of a doubly fed induction generator stator connected to a dc net by a diode rectifier , 2014 .

[5]  Guillermo O. García,et al.  Adaptive Observer for Sensorless Control of Stand-Alone Doubly Fed Induction Generator , 2009, IEEE Transactions on Industrial Electronics.

[6]  Yongzheng Zhang,et al.  Sensorless Maximum Power Point Tracking of Wind by DFIG Using Rotor Position Phase Lock Loop (PLL) , 2009, IEEE Transactions on Power Electronics.

[7]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.

[8]  Greg Asher,et al.  A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine , 1996 .

[9]  Dehong Xu,et al.  Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator , 2012, IEEE Transactions on Power Electronics.

[10]  G. D. Marques,et al.  Enhanced torque control in a DFIG connected to a DC grid by a diode rectifier , 2014, 2014 16th European Conference on Power Electronics and Applications.

[11]  Heng Nian,et al.  Direct Power Control of Doubly Fed Induction Generator Under Distorted Grid Voltage , 2014, IEEE Transactions on Power Electronics.

[12]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[13]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[14]  Hiroaki Kakigano,et al.  Low-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution , 2010, IEEE Transactions on Power Electronics.

[15]  Hong-Hee Lee,et al.  Control Strategy for Harmonic Elimination in Stand-Alone DFIG Applications With Nonlinear Loads , 2011, IEEE Transactions on Power Electronics.

[16]  J. Jatskevich,et al.  Parametric average-value model of synchronous machine-rectifier systems , 2006, IEEE Transactions on Energy Conversion.

[17]  Dong Chen,et al.  Control and Operation of a DC Microgrid With Variable Generation and Energy Storage , 2011, IEEE Transactions on Power Delivery.

[18]  Gil D. Marques,et al.  Torque Ripple Reduction in a DFIG-DC System by Resonant Current Controllers , 2015, IEEE Transactions on Power Electronics.