Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with helical screw-tape inserts

Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with full-length helical screw element of different twist ratio, and increasing and decreasing order of twist ratio set have been studied with uniform heat flux. The experimental data obtained are compared with those obtained from plain tube published data. The heat transfer coefficient increases with twist ratio. There is no much change in the magnitude of heat transfer coefficient enhancement with increasing twist ratio and with decreasing twist ratio set, as the magnitude of swirl generated at the inlet or at the outlet in the order of increasing twist ratio or decreasing twist ratio, is same in both the cases. The empirical correlations developed in terms of twist ratio and Reynolds number, are fitting the experimental data within plus or minus 15% and 13% for Nusselt number and friction factor, respectively.

[1]  Arthur E. Bergles,et al.  Augmentation of highly viscous laminar heat transfer inside tubes with constant wall temperature , 1989 .

[2]  Animesh Dutta,et al.  Friction and heat transfer characteristics of laminar swirl flow through a circular tube fitted with regularly spaced twisted-tape elements , 2001 .

[3]  Arthur E. Bergles,et al.  Some perspectives on enhanced heat transfer: second-generation heat transfer technology , 1988 .

[4]  M. Raja Rao,et al.  Heat transfer augmentation for the flow of a viscous liquid in circular tubes using twisted tape inserts , 1996 .

[5]  A. Patil Laminar Flow Heat Transfer and Pressure Drop Characteristics of Power-Law Fluids Inside Tubes With Varying Width Twisted Tape Inserts , 2000 .

[6]  E. N. Sieder,et al.  Heat Transfer and Pressure Drop of Liquids in Tubes , 1936 .

[7]  Pongjet Promvonge,et al.  Enhancement of heat transfer in a tube with regularly-spaced helical tape swirl generators , 2005 .

[8]  F. Landis,et al.  Friction and Forced Convection Heat-Transfer Characteristics in Tubes With Twisted Tape Swirl Generators , 1964 .

[9]  A. W. Date,et al.  Prediction of fully-developed flow in a tube containing a twisted-tape , 1974 .

[10]  A. Ferrero,et al.  Measurement uncertainty , 2006, IEEE Instrumentation & Measurement Magazine.

[11]  W. Chakroun,et al.  The Effect of Twisted Tape Width on Heat Transfer and Pressure Drop for Fully Developed Laminar Flow , 1995 .

[12]  S. F. Al-Fahed,et al.  Pressure drop and heat transfer comparison for both microfin tube and twisted-tape inserts in laminar flow , 1998 .

[13]  R. M. Manglik,et al.  Heat Transfer and Pressure Drop Correlations for Twisted-Tape Inserts in Isothermal Tubes: Part I—Laminar Flows , 1993 .

[14]  W. Rohsenow,et al.  Handbook of heat transfer applications , 1985 .

[15]  Qiang Liao,et al.  Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts , 2000 .

[16]  S. W. Hong,et al.  Augmentation of Laminar Flow Heat Transfer in Tubes by Means of Twisted-Tape Inserts , 1974 .

[17]  R. M. Manglik,et al.  Heat Transfer and Pressure Drop Correlations for Twisted-Tape Inserts in Isothermal Tubes: Part II—Transition and Turbulent Flows , 1993 .