Assessment of the status of insulation during thermal stress accelerated experiments on transformer prototypes

The status of insulation in power equipment at any given point in time can be assessed by monitoring properties which are sensitive to the amount of aging. This procedure, called the diagnostic or non-destructive testing, has been in vogue for some time now. The diagnosis, as the name suggests, enables one to disseminate the condition of the insulation by making terminal or enclosure-centric measurements and as applied to transformers, a minimally invasive test procedure involving the examination of the oil phase, for arriving at information on the degradation of the cellulose insulation on the winding is indicated. An examination of the tracks provided by the by-products of chemical dissociation of cellulose, in solution with oil is recognized as a possible approach to condition monitoring. To this end, carefully controlled laboratory aging experiments have been performed on eight, nominally identical and scaled-down (pro-rated) models of single phase transformer units, incorporating all the essential features of actual power transformers under normal operating electric stress and accelerated thermal stress. Acquisition, analysis and validation of experimental data including dissolved gas analysis (DGA), examination of oil phase for the presence of Furans, measurement of the degree of polymerization (DP) of the paper insulation, electrical and certain chemical tests have all been performed to evolve an experimental data-base for assessing condition of insulation.

[1]  M.K. Pradhan,et al.  On the estimation of elapsed life of oil-immersed power transformers , 2005, IEEE Transactions on Power Delivery.

[2]  V. M. Montsinger Loading Transformers By Temperature , 1930, Transactions of the American Institute of Electrical Engineers.

[3]  J. Unsworth,et al.  Degradation of electrical insulating paper monitored with high performance liquid chromatography , 1990 .

[4]  M.K. Pradhan,et al.  Diagnostic testing of oil-impregnated paper insulation in prorated power transformers under accelerated stress , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.

[5]  T. Suzuki,et al.  Degradation of Insulating Materials of Transformers , 1987, IEEE Transactions on Electrical Insulation.

[6]  Y. Makino,et al.  Absorption of CO/sub 2/ and CO gases and furfural in insulating oil into paper insulation in oil-immersed transformers , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[7]  T. S. Ramu,et al.  Prediction of hottest spot temperature (HST) in power and station transformers , 2003 .

[8]  A. W. Stannett,et al.  A review of paper aging in power transformers , 1985 .

[9]  M.K. Pradhan,et al.  Criteria for estimation of end of life of power and station transformers in service , 2004, The 17th Annual Meeting of the IEEE Lasers and Electro-Optics Society, 2004. LEOS 2004..

[10]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. I. Factors affecting the measurement of the average viscometric degree of polymerisation of new and aged electrical papers , 2000 .

[11]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil , 2000 .

[12]  M.K. Pradhan,et al.  Estimation of the hottest spot temperature (HST) in power transformers considering thermal inhomogeniety of the windings , 2004, IEEE Transactions on Power Delivery.

[13]  G. C. Stevens,et al.  Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers , 1994 .

[14]  Jun Zhang,et al.  Expediting cellulose insulation aging evaluation and life prediction through degree of polymerization measurements , 1988, Proceedings., Second International Conference on Properties and Applications of Dielectric Materials.