Tunable diode laser measurements of air-broadened linewidths in the nu6 band of H2O2

Air-broadened half-widths of 18 transitions in the nu6 band of H2O2 between 1252/cm and 1291/cm have been determined from spectra recorded at room temperature using a tunable diode laser spectrometer. The preparation of the H2O2 gas samples for the measurements is described, and the data analysis is discussed, including the derivation of Lorentz broadening coefficients and the contribution of molecular collisions to the measured Lorentz half-widths. For the 18 transitions, the half-widths varied from 0.0923/cm/atm to 0.1155/cm/atm at 296 K, with a mean value of 0.1020/cm/atm. An error of less than 10 percent is estimated for these results.